8 The following Information would be added to the header shown in step 3, assuming the "Accept Failure
Location Codes" field contains a "Y".
BOND
PULL (gf)
LOCATION ERROR
1 12.3
gf 1
2
.5 gf
NO TEST/OPERATOR
2 12.2
gf 1
3 12.0
gf 1
4 12.2
gf 1
5 13.2
gf 1
6 13.3
gf 1
7 13.5
gf 1
8 14.2
gf 1
9 13.0
gf 1
10 12.6
gf 1
11 12.5
gf 1
12 12.8
gf 1
13 13.1
gf 2
14 11.7
gf 1
15 11.5
gf 1
16 11.7
gf 1
Serial
Number:
1015
No. of Tests:
16
Aver. Pull Strength:
12.6 gf
Standard Deviation:
0.7 gf
Standard
Deviation: 5.8%
Aver. – 3 (Std Dev.):
10.4 gf