CHAPTER 3: OPERATING INSTRUCTIONS
MICROPULL
®
IV WIRE BOND PULL TESTER
3-12
990-180
NON-DESTRUCTIVE PULL TEST
Date:
12-06-1987 14:23
Operator: M.P.
PHFOUR
Part No:
A1234567890
Lot No:
4-234-789
Beam Size:
100 gf
Pull Test Limit:
2.5 - 2.7 gf
No. Bonds / Device:
16
Serial
No:
1005
The following will be displayed on the computer screen:
NON-DESTRUCT TESTING
TEST
PULL(gf)
Start Testing
2 During Non-Destruct Testing the function keys, which are displayed in reverse video at the bottom of
the screen, have the meanings shown below:
NOTE:
The function keys are inoperative whenever the computer is waiting for the operator to enter a new
serial number. Therefore, if it is necessary to use a function key as part of serial number entry, press
<Enter> prior to pressing the necessary function key.
KEY DEFINITION
Fl
That was the last test.
Print results and gets ready for next device.
F3
End testing, return to Change Header screen.
F4
End testing, return to Configure Hardware screen.
F7
The last test was invalid. Ignore this data.
F10 Exit
program