fumée 

de l'appar

eil dans 

la pièc

e à 

trav

ers les 

joints 

de l'appar

eil 

et du c

onnecteur de cheminée

. Une br

ûlure inc

ontr

ôlable ou une 

tempér

atur

e exc

essiv

e indique un tirag

e exc

essif

.

RA

CCORDEMENT D

U CONNE

CTEUR 

DE CHEMINÉE À UNE CHEMINÉE DE 

MAÇONNERIE À TR

AVER

S UN MUR 

COMB

USTIBLE

CHEMINÉE EN 

MAÇONNERIE 

CONSTRUITE SELON 

NFPA 211

PORTE DE 

NETTOYAGE 

ÉTANCHE

PROTECTEUR 

DE PLANCHER

MUR COMBUSTIBLE

VERS LE 

CHAUFFAGE

CONDUIT DE 

RACCORDEMENT

PLAFOND

VOIR LES PIÈCES 

A, B, C, D, ET E DE 

CETTE FIGURE 

POUR LES OPTIONS.

CONDUIT DE CHEMINÉE

CONNEXION DU CONDUIT DE RACCORDEMENT 

À UNE CHEMINÉE DE MAÇONNERIE, 

À TRAVERS UN MUR COMBUSTIBLE

(SUITE DE LA FIGURE 8 À LA PAGE SUIVANTE)

ATTENTION:

ASS

UREZ-V

OU

S Q

UE VO

TRE CHEMINÉE ES

CONS

TRUITE 

EN TO

UTE SÉCURITÉ ET 

EN BONNE 

RÉPAR

ATION. F

AITES INSPE

CTER L

A CHEMINÉE PAR LE 

SERVICE DE

S INCENDIES O

U UN INSPECTEUR Q

UALIFIÉ.

Les fig

ures de c

e manuel montr

ent c

omment c

onnecter le 

rac

cor

d de cheminée d'un appareil de cha

uffag

e à une cheminée 

en maçonnerie à tr

aver

s un mur combus

tible. U

n rac

cor

d de 

cheminée peut êtr

e rac

cor

dé à une cheminée de maçonnerie de 

cinq faç

ons po

ssibles 

en pa

ssan

t à 

trav

ers 

un mur 

combus

tible. 

La 

norme NFP

A 211 

aut

orise 

les sy

stèmes 

trav

ersan

ts 

muraux 

suiv

ants.

1. 

Utilis

ez un enc

adremen

t de briqueta

ge d’

au moins 9 cm (

3-

1/2 po

) d’épais

seur dans le mur c

ombustible

. Un doubla

ge 

d’ar

gile réfr

actair

e (AS

TM C315 ou un équivalen

t) a

yan

une épais

seur 

de par

oi d’

au 

moins 16 

mm (5

/8 

po) doit 

êtr

utilisé e

t doit êtr

e situé à a

u moins 30 cm (

12 po) de t

out 

matéria

u pouvan

t s’en

flammer. L

e diamètr

e intérieur du 

doublage d’

argile r

éfr

actair

e doit êtr

e d’une t

aille pouvan

s’ajus

ter de manièr

e serr

ée à un conduit de r

accor

dement 

de 15 cm (6 po

). Le doubla

ge d’

argile r

éfr

actair

e doit pass

er 

de la sur

fac

e ext

érieure du mur de brique

, jusqu’

à ne pas 

dépass

er la sur

fac

e intérieur

e du conduit de f

umée, en plus 

d’êtr

e cimenté en plac

e.

Le dégagement minimum de la cheminée à la brique et les

matériaux combustibles est de 5 cm (2 po) (50,8 mm)

30 cm (304,8 mm, 12 po)

minimum aux matériaux

combustibles

Cheminée en

maçonnerie

Conduit de cheminée

Doublage en

argile réfractaire

Conduit de

raccordement

Dégagement minimum

de 30 cm (12 po, 

304,8 mm)

des briques 

2. 

Utilis

ez une long

ueur de cheminée préf

abriquée réper

toriée

au diamè

tre in

térieur de 15 cm (

6 po) e

t à isolan

t solide 

d’une 

épaisseur 

de 25 

mm (1 

po). 

Le 

vide d’

air en

tre 

la par

oi 

ext

érieure de la long

ueur de cheminée et t

out matéria

combus

tible doit êtr

e d’au moins 2

3 cm (9 po

). L’ex

trémit

é 

intérieur

e de 

la long

ueur de 

cheminée doit 

êtr

e à 

égalit

é 

avec l’

intérieur de la cheminée en maç

onnerie, la cheminée 

doit êtr

e scellée à s

on extr

émité à l’

entr

ée du briqueta

ge, 

avec un cimen

t réfr

actair

e insoluble par l’

eau. Des s

upports 

de tôle d’

acier d’un c

alibre d’

au moins 2

4 (0.

024 po

d’épais

seur doiv

ent ê

tre s

olidement fix

és aux s

urfac

es 

murales, s

ur tous les c

ôtés. L

es att

aches entr

e les suppor

ts 

et la long

ueur de cheminée ne doiven

t pas péné

trer dans le 

doublage de cheminée

.

Le dégagement minimum de la cheminée à la brique et les

matériaux combustibles est de 5 cm (2 po) (50,8 mm)

Conduit de

cheminée

Conduit de

raccordement

Dégagement 

minimum de 5 cm 

(9 po) (228,6 mm)

Nonsoluble

refractory

cement

Supports de

tôle d'acier

Cheminée en

maçonnerie

Utiliser des pièces

de cheminée

fabriquées pour

le fixer solidement

au raccordement.

Vide d’air

Longueur de

cheminée

préfabriquée et

répertoriée, à

isolant solide.

Minimum Vide d’air

de 5 cm (9 po)

(228,6 mm)

Longueur de

cheminée 

préfabriquée

Longueur de cheminée 

à égalité avec le conduit 

de fumée intérieur

3. 

Utilis

ez une vir

ole ven

tilée de 25 cm (

10 po) de diamè

tre, 

compo

sée d’

acier d’un c

alibre de 2

4 (0.

024 po

) compor

tan

deux cana

ux d’aér

ation de 2

5 mm (1 po

). La vir

ole ven

tilée 

doit êtr

e sépar

ée des matéria

ux combus

tibles par un 

minimum de 15 cm (6 po

) d’is

olant en fibr

e de verr

e. 

L’ouv

ertur

e dans le mur combus

tible doit êtr

e couv

erte 

et la vir

ole doit êtr

e sout

enue par des suppor

ts de t

ôle 

INSTALL

ATION

Summary of Contents for US1269E

Page 1: ...tallation of this heater Contact local building or fire officials about permits restrictions and installation requirements in your area NEVER OPERATE THIS PRODUCT WHILE UNATTENDED CAUTION Please read...

Page 2: ...EPA test conditions burning Douglas Fir dimensional lumber this heater has been shown to deliver heat at a rate of 29 234 to 26 300 Btu hr This heater achieved a particulate emissions rate of 1 8 g h...

Page 3: ..._________________________________________ If no Date of inspection of the existing chimney system ___________________________________________________________ COMMISSIONING Confirm Hearth Pad Installat...

Page 4: ...ney Furnace Cement Flooring protector as specified NOTICE UNITED STATES STOVE COMPANY GRANTS NO WARRANTY STATED OR IMPLIED FOR THE INSTALLATIONORMAINTENANCEOFYOURWOOD STOVE AND ASSUMES NO RESPONSIBILI...

Page 5: ...h a handle bracket This bracketed leg is designed to be installed at the front right side of the unit X 2 X 2 7 Attach the rear legs to the base of the stove with two 2 M8 X 45 screws and two 2 M8 X 4...

Page 6: ...R TO A TYPE B GAS VENT THIS IS NOT SAFE AND IS PROHIBITED BY THE NATIONAL FIRE PROTECTION ASSOCIATION CODE THIS HEATER REQUIRES APPROVED MASONRY OR UL ULC LISTED RESIDENTIAL TYPE AND BUILDING HEATING...

Page 7: ...pe and or elbow joint to firmly hold the pipe together Seal around the screws Do not install this heater in a mobile home or trailer Check with local codes The installation must comply with their ruli...

Page 8: ...orizontal pipe upward toward the chimney at least 1 4 for each foot of horizontal run The horizontal section must be a minimum of 24 from the stove 3 You must have at least 18 inches clearance between...

Page 9: ...from any material that could catch fire The inside diameter of the fireclay liner shall be sized for the proper snug fit of a 6 diameter chimney connector pipe The fireclay liner shall run from the o...

Page 10: ...s shown for 3 and 4 above Parts C and D respectively of Figure 8 shall be for types 3 and 4 connections to facilitate removal of the chimney connector for cleaning The chimney thimble shall be of ASTM...

Page 11: ...Smoke spillage into the house or excessive buildup of water or creosote in the chimney are warnings that the chimney is not functioning properly Correct problem before using heater Possible causes ar...

Page 12: ...n burning air dried seasoned hardwoods as compared to softwoods or too green or freshly cut hardwoods The following resources can assist in learning the burn characteristics of various species of wood...

Page 13: ...the ends of the piece your wood is soaked or freshly cut green Do not use this wood in your stove Large amounts of creosote could be deposited in your chimney creating potential conditions for a chim...

Page 14: ...the air inlet 5 Reloading of fuel should only occur once the prior fuel load has burned down to embers Abiding by this routine your stove will achieve the cleanest emissions burn plus will prevent ove...

Page 15: ...ays check for creosote deposit once every two months and have your chimney cleaned at least once a year If a chimney or creosote fire occurs DO NOT open the door keep the door closed Wait for the fire...

Page 16: ...16 2021 United States Stove Company REPAIR PARTS 1 2 3 4 5 6 7 9 11 10 8 16 15 14 13 12 18 19 20 21 22 23 17 24...

Page 17: ...1 22 892511 Door Panel Front 1 23 892843 Door Pin 2 24 893216 Door Assembly 1 To order parts Call 1 800 750 2723 Ext 5051 or Email to parts usstove com For Parts Assistance Call 800 750 2723 Ext 5051...

Page 18: ..._____ Engineer Name _____________________________________ License No _________________________________________ Company ___________________________________________ Telephone No ________________________...

Page 19: ...ce de 07 Date ______________________ Nom de l ing nieur _________________________________ N de licence ______________________________________ Compagnie ________________________________________ N de t...

Page 20: ...de corde 3 8 1 21 88174 Joint de fen tre 1 8x1 1 22 892511 Panneau de porte 1 23 892843 Goupille de porte 2 24 893216 Assemblage de porte 1 COMMANDE DE PI CES DE RECHANGE Les informations contenues da...

Page 21: ...16 2021 United States Stove Company PI CES DE RECHANGE 1 2 3 4 5 6 7 9 11 10 8 16 15 14 13 12 18 19 20 21 22 23 17 24...

Page 22: ...r osote V rifiez toujours le d p t de cr osote une fois tous les deux mois et faites nettoyer votre chemin e au moins une fois par an Si un feu de chemin e ou de cr osote se produit N OUVREZ PAS la po...

Page 23: ...l es plus emp chera le surfiage de votre po le FUM E VISIBLE La quantit de fum e visible produite peut tre une m thode efficace pour d terminer l efficacit du processus de combustion aux param tres d...

Page 24: ...dans votre chemin e cr ant des conditions potentielles pour un feu de chemin e ALT RER AVERTISSEMENT Ce chauffage au bois a un taux de combustion minimum r gl la fabrication et qui ne peut tre modifi...

Page 25: ...ents nerg tiques que d autres Des rendements plus lev s et des missions plus faibles r sultent g n ralement de la combustion de bois durs s ch s l air par rapport aux r sineux ou aux feuillus trop ver...

Page 26: ...Le dispersement de fum e dans la maison ou une accumulation excessive d eau ou de cr osote dans la chemin e est un avertissement que la chemin e ne fonctionne pas correctement Corrigez le probl me av...

Page 27: ...es directives qui l accompagnent offrant une m thode s curitaire pour faire traverser le conduit de raccordement travers un mur combustible en vue d un branchement une chemin e en ma onnerie EXIGENCES...

Page 28: ...s d tre ciment en place Le d gagement minimum de la chemin e la brique et les mat riaux combu ibles e de 5 cm 2 po 50 8 mm 30 cm 304 8 mm 12 po minimum aux mat riaux combu ibles Chemin e en ma onnerie...

Page 29: ...e au moyen de 3 vis puis scell avec du ciment calorif re 2 Appliquez une pente minimale de 6 mm 1 4 po par 30 cm 1 pi de conduit horizontal de tuyau en direction de la chemin e La section horizontale...

Page 30: ...lisez trois vis auto taraudeuses dans chaque tuyau de po le ou joint coud pour maintenir solidement le tuyau Scellez le pourtour des vis N installez pas ce chauffage dans une maison mobile V rifiez vo...

Page 31: ...ITS ENFANTS NE DEVRAIENT PAS TRE LAISS S SANS SUPERVISION QUAND DANS LA CHAMBRE AVEC LE CHAUFFAGE CET APPAREIL NE DOIT PAS TRE UTILIS COMME SOURCE PRIMAIRE DE CHALEUR AVIS DE S CURIT NE PAS RACCORDER...

Page 32: ...oign e Ce pied support est con u pour tre install sur le c t avant droit de l unit X 2 X 2 7 Fixez les pieds arri re la base du po le avec deux 2 vis M8 X 45 et deux 2 crous M8 X 45 X 2 X 2 8 Soulevez...

Page 33: ...de sol tel que sp cifi ATTENTION LE PO LE EST LOURD ASSUREZ VOUS D AVOIR SUFFISAMMENT D AIDE ET D UTILISER LES TECHNIQUES APPROPRI ES DE LEVAGE LORSQUE VOUS D PLACEZ LE PO LE AVIS UNITED STATES STOVE...

Page 34: ...ion du syst me de chemin e existant ____________________________________________________________________ MISE EN SERVICE Confirmer l installation du tapis de foyer conform ment aux instructions d inst...

Page 35: ...ectrique Aucun Dimensions G n ral profondeur x largeur x hauteur 838 x 470 x 584 mm 33 x 18 5 x 23 po Chambre de combustion Largeur x profondeur 229 mm x 482 9 x 19 po Volume M tres cubes pieds cubes...

Page 36: ...sables locaux du b timent ou des pompiers pour conna tre les permis les restrictions et les exigences d installation dans votre r gion NE JAMAIS UTILISER CE PRODUIT SANS SURVEILLANCE MISE EN GARDE Veu...

Reviews: