4
Furnace Installation
Dimension
Inches
mm
A
Backwall to Appliance
17
432
B
Sidewall to Appliance
12
305
C
Backwall to Flue
23
585
D
Sidewall to Flue
22.5
572
E
Supply Duct (first 6 feet)
6
153
F
Supply Duct (after first 6 feet)
1
26
G Minimum Duct height
6
153
H
Ceiling Height to Floor
84
2134
J
Top of Door to Ceiling
48
1220
*
Closest Point of Zero Clearance
2’
610
Ceiling
E
F
J
H
G
Back wall
Side w
all
Side w
all
B
D
A
C
CLEARANCE TO COMBUSTIBLES
CLEARANCE TO COMBUSTIBLES
INSTALLATION OPTIONS
The installation of this furnace includes supplying electrical power, return (fresh air) ductwork, and supply air
ductwork. This furnace may be installed as a stand alone wood furnace.
See kit installation section in this manual to ensure proper assembly, installation and operation of your new
furnace.
If installing in an area with a fan it should not be allowed to create negative pressure in the room where the
furnace is installed.
LOCATING YOUR FURNACE
(INSURE THAT THE REQUIRED MAINTENANCE CLEARANCES ARE MAINTAINED)
Your furnace must be installed as shown in this manual and in compliance with all local and national codes.
It is of the utmost importance that the clearances to combustible materials be strictly adhered to during
installation of the furnace. Refer to the table and diagrams below for minimum required clearances.