4.

 

Date Format (default: DD-MM): 

Press the 

SET

 key again to enter the day/month format mode. Press the [+] key to 

switch between M-D, D-M.

   

5.

 

Change Month.

 Press the 

SET

 key again to set the calendar month. Press the [+] key or [

-

] key to adjust the calendar 

month.  

6.

 

Change Day.

 Press the 

SET

 key again to set the calendar day. Press the [+] key or [

-

] key to adjust the calendar day.   

7.

 

Change Year. 

Press the 

SET

 key again to set the calendar year. Press the [+] key or [

-

] key to adjust the calendar 

year.   

8.

 

Weather Forecast Icon Setting (default: partly cloudy)

. Press the 

SET

 key again to set the weather forecast icon 

initial conditions (based on the current weather conditions). Press the [+] key or [

-

] key to toggle weather icons 

between sunny, partly cloudy, cloudy, or rainy.

 

9.

 

Time SYNC(

default:ON).

Press the SET key again to set the network time sync.    Press the [+] key or [-] key to switch 

between SYNCtime ON and SYNCtime OFF of measure.

 

5.2

 

Chanel

 

Selection

 

Press the 

CHANNEL

 button to switch the display between remote thermo-hygrometer sensors 

1 through 3. 

In normal mode, press the "CHANNEL" key switch to set the area (CH1, CH2, CH3 icon single 
flashing 5 seconds), and press the "CHANNEL" key for 3 seconds to re-learn the current 
flashing guide, can clear the current channel outdoor unit , and re-search the current channel 
for 3 minutes. When searching, the channel will be re-registered 

 

5.3

 

Reset

 

Min/Max

 

record

 

 
Press the 

MIN/MAX

 button once to check the 

MAX

 values, press and hold the 

MIN/MAX

 button 

for 3 seconds to restore the 

MAX

 values to the current value. 

Press the 

MIN/MAX 

  button once again to check the 

MIN

 values, press and hold the 

MIN/MAX

 

button for 3 seconds to restore the 

MIN

 values to the current value. 

When complete, press the 

MIN/MAX

 button again, and the display will return to normal mode. 

In the maximum and minimum query mode, 15 seconds without operation will automatically 
return to normal mode 

Note:

 

The minimum and maximum can be set to clear every 24 hours automatically. Press and hold the 

MIN/MAX

 

button for 3 seconds to switch between 

Clears 24h

 and Clears Manually.

 

When you manually clear the minimum and maximum, the Clears 24h function will be a day when the 0:00 time 
automatic clearance.

 

5.4

 

Sensor

 

Search

 

Mode

 

If any of the sensor communication is lost, dashes (--.-) will be displayed on the screen. To 
reacquire the signal:   

1.  If a specific channel is lost, press the 

C

 button until the channel indication 

single flashing. 
Press and hold the 

CHANNEL

 button for 3 seconds, and the remote search icon 

 will 

be constantly displayed for up to 10 minutes. 
Once the signal is reacquired, the remote search icon 

  will turn off, and the current 

Summary of Contents for FT0851

Page 1: ...e FT0851 weather station consists of the following parts as referenced in Figure 1 QTY Item 1 Display Console Frame Dimensions LxHxW 135X195X26mm LCD Dimensions LxW 112 x 63mm 3 Thermo hygrometer sens...

Page 2: ...1 Display Console Layout The display console layout is shown in Figure 2 Note The following illustration shows the full segment LCD display for description purposes only and will not appear like this...

Page 3: ...he console or the console will time out searching for the sensors Power the console last Make certain the weather station sensor array is at least 3m away from the console and within 30m of the consol...

Page 4: ...Allow about 30 minutes for both sensors to stabilize 2 Verify proper operation of the indoor and outdoor humidity Verify the indoor and outdoor humidity match closely with the console and sensor arra...

Page 5: ...on range by the factor shown below Medium RF Signal Strength Reduction Glass untreated 5 15 Plastics 10 15 Wood 10 40 Brick 10 40 Concrete 40 80 Metal 90 100 3 2 Remote Sensor Installation If you moun...

Page 6: ...SNOOZE LIGHT button CHANNEL button on the top and SET button ALARM button and C F WiFi button on the right side Note WiFi Settings reference 10 STEP 5 1 Set Program Mode While in Normal Mode press an...

Page 7: ...e current channel outdoor unit and re search the current channel for 3 minutes When searching the channel will be re registered 5 3 Reset Min Max record Press the MIN MAX button once to check the MAX...

Page 8: ...n on for five seconds and if no operation is performed for three seconds the backlight will turn off Press and hold the LIGHT key for two seconds and the backlight will turn on permanently and display...

Page 9: ...e will begin flashing Press the or key to increase or decrease the temperature reading in increments of 0 1 Press and hold the or key for three seconds to increase or decrease rapidly Press the ALARM...

Page 10: ...of time In normal mode Press and hold the ALARM key for three seconds to enter the alarm1 settings mode The alarm parameter will begin flashing In alarm mode press the SET key to the alarm2 settings m...

Page 11: ...e server to obtain the time Once the connection succeeds and the console s time has updated the SYNC icon will appear on the LCD The time will automatically synchronize to the internet per an hour Not...

Page 12: ...t phone tablet or computer to connect to the console through WiFi Note that when the console programming is complete you will resume your default WiFi connection Note that you cannot connect two or mo...

Page 13: ...nnect to the WeatherHome WiFi network as shown in Figure 9 your WiFi network name may be slightly different but will always begin with WeatherHome Figure 9 10 4 Example 4 Connect to the console WiFi s...

Page 14: ...e following information into the web interface Figure 11 Make sure all of the information is entered prior to selecting Save If you choose not to use Upload Wunderground com Upload AmbientWeather net...

Page 15: ...ve a hidden SSID enter the SSID manually Time Zone Settings default 0h based on the number of hours from Coordinated Universal Time or Greenwich Mean Time GMT The following table provides times zones...

Page 16: ...CET Central European Paris France 2 EET Eastern European Athens Greece 3 BT Baghdad Moscow Russia 4 Abu Dhabi UAE 5 Tashkent 6 Astana 7 Bangkok 8 CCT China Coast Bejing 9 JST Japan Standard Tokyo 10...

Page 17: ...ure If the data signal icon is updata to weather servers the icon will flash If the icon disappears it means the console is not connected to the weather servers more than half an hour or no choose the...

Page 18: ...ew your data as shown in Figure 16 Figure 16 AmbientWeather net is a responsive design and mobile friendly so there is no need for a mobile app Simply open your mobile devices web browser browse to Am...

Page 19: ...derground com personal weather station dashboard ID STATIONID where STATIONID is your personal station ID example KCALOSAN782 Figure 18 Note The current temperature and humidity data is the transmitte...

Page 20: ...connects to IFTTT the platform that allows devices and services to work together seamlessly Here are a few things you can do with IFTTT Turn off your Rachio sprinklers when it rains there is too much...

Page 21: ...t Link your account to get started say hey google Ambient Weather weather report This will provide you with your outdoor weather report You can ask for your indoor weather report as well by saying ind...

Page 22: ...Note This is best done on a computer desktop or laptop 10 15 6 Visit https weathercloud net and enter a Username Email and Password as shown in Figure 22 Figure 22 10 15 7 Respond to the validation e...

Page 23: ...p AC the console or press and hold the MIN MAX WiFi button for three seconds in normal mode the console icon above the DAY icon will flash to signify that it has entered WAP wireless access point mode...

Page 24: ...cally restart it is not the console to reset 11 7 Once the upgrade is completed the console will automatically exit WAP mode 12 Specifications 12 1 Wireless Specifications Line of sight wireless trans...

Page 25: ...WAP mode smart device including laptops computers smart phones and smart pads 4 Recommend web browser for setup UI Web browser support of HTML 5 such as the latest versions of Chrome Safari IE Edge Fi...

Page 26: ...ay time Make sure the thermo hygrometer is mounted in a shaded area The pre preferred location is a north facing wall because it is in the shade most of the day Indoor and Outdoor Temperature do not a...

Page 27: ...an be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Incre...

Reviews: