![Unipulse F377A Operation Manual Download Page 111](http://html.mh-extra.com/html/unipulse/f377a/f377a_operation-manual_843484111.webp)
1
EXP. HOLD FUNCTIONS
110
EXP. HOLD FUNCTIONS
Chapter
1
* OK is displayed each on the LCD screen as hold value A is OK, and hold value B is OK.
1-2.
Sample Hold Trigger Edge Selection
You can select the input timing of the SECTION signal to perform sample hold from ON edge and
OFF edge.
However, OFF-edge operation can be performed only when a Hold Section exists.
FCN-365P024-AU/FCN-360C024-B
External I/O
A1
-
COM1
COM2
-
B1
A2
Out
HI-B
WORK0
IN
B2
A3
Out
HI-A
WORK1
IN
B3
A4
Out
OK
WORK2
IN
B4
A5
Out
LO-A
WORK3(LOCK)
IN
B5
A6
Out
LO-B
T/H
IN
B6
A7
-
COM1
COM2
-
B7
A8
Out
HOLD END(H/E)
SECTION
IN
B8
A9
Out
RUN
DIGITAL ZERO
IN
B9
A10
Out
EVENT
GRAPH TRIG
IN
B10
A11
Out
SIF
CAL0
IN
B11
A12
Out
SIF
CAL1
IN
B12
- External I/O pin assignments for Double Hold
Sensor Input Value
䋨
Hold Value B
䋩
Hold Value A
Hold Value A
Sensor Input Value
䋨
Hold Value B)
----(A)
Status Display
Status Display
Status Display
Status Display
SECTION
SECTION
T/H
H/E
T/H
H/E
----(B)
Status Display
Blink
HOLD
䋨
A
䋩
OFF
HOLD
䋭
B
OFF
Status Display
Status Display
Status Display
Blink
ON
Blink
HOLD
䋭
B
OFF
----(A)
HOLD
䋨
A
䋩
Blink
ON
OFF
OFF
----(B)
OFF
●
In the case of ON-edge operation
where the hold modes are
A: Sample hold
B: None
●
In the case of OFF-edge operation
where the hold modes are
A: Sample hold
B: None
Summary of Contents for F377A
Page 1: ...18JUL2012REV 3 06 DIGITAL INDICATOR F377A OPERATION MANUAL ...
Page 5: ...What is RoHS 4 M E M O ...
Page 12: ...11 11 STANDARD ...
Page 13: ...12 12 M E M O ...
Page 94: ...93 93 EXPANSION ...
Page 95: ...94 94 M E M O ...
Page 97: ...Expansion Function 96 M E M O ...
Page 152: ......