EXP. HOLD FUNCTIONS
102
EXP. HOLD FUNCTIONS
Chapter
1
8.
A: Sample hold
B: Peak hold
An arbitrary point is held when the SECTION signal is ON.
The maximum value in the section specified is held.
The value is maintained until the T/H signal turns ON.
9.
A: Sample hold
B: Valley hold
An arbitrary point is held when the SECTION signal is ON.
The minimum value in the section specified is held.
The value is maintained until the T/H signal turns ON.
Sensor Input Value
Hold Value B
Hold Value A
SECTION
----(A)
H/E
OFF
HOLD
䋨
B
䋩
Blink
ON
OFF
ON
OFF
OFF
Blink
OFF
ON
HOLD
䋨
A
䋩
Blink
Status Display
Status Display
Status Display
Status Display
PEAK
䋨
B
䋩
T/H
Hold Value A
Sensor Input
Value
Hold Value B
H/E
SECTION
T/H
HOLD
䋨
A
䋩
Blink
ON
Blink
Status Display
----(A)
OFF
HOLD
䋨
B
䋩
OFF
ON
OFF
Status Display
Status Display
VLLY
䋨
B
䋩
OFF
Blink
ON
Status Display
OFF