![Unipulse F350 Operation Manual Download Page 78](http://html.mh-extra.com/html/unipulse/f350/f350_operation-manual_843505078.webp)
65
9
OPTION INTERFACE
65
OPT
ION INT
E
RFA
C
E
Chapter
9
●
Input
■
Connector pin assignment
Compatible connector: FCN-361J032-AU (manufactured by FUJITSU COMPONENT or equivalent)
Connector cover:
FCN-360C032-B (manufactured by FUJITSU COMPONENT or equivalent)
(connector & cover optional type: CN51)
CAUTION
●
Do not apply external voltage to the signal input circuit.
●
The external element is required to withstand Ic=10mA.
●
Leakage from the external element is required to be 30
μ
A or below.
A1
*
COM
B1
*
COM
A2
OUT
1
B2
OUT
1000
A3
OUT
2
B3
OUT
2000
A4
OUT
4
B4
OUT
4000
A5
OUT
8
B5
OUT
8000
A6
OUT
10
B6
OUT
10000
A7
OUT
20
B7
OUT
20000
A8
OUT
40
B8
OUT
40000
A9
OUT
80
B9
OUT
80000
A10
OUT
100
B10
OUT
Minus (Polarity)
A11
OUT
200
B11
OUT
OVER
A12
OUT
400
B12
OUT
STAB
A13
OUT
800
B13
OUT
STROBE
A14
IN
Data Hold
B14
IN
Logic Switching
A15
IN
Data Switching 0
B15
IN
Data Switching 1
A16
-
B16
-
Transistor
TTL open collector output
Open
OFF
Short
ON
Vcc
+5V
IC=Approx.6mA
COM
Switch
Inside Outside
F350
(ON when IN is HI)
Summary of Contents for F350