49
6
EXPLANATION OF COMPARISON FUNCTIONS
49
EX
PLANATION OF COMPARIS
ON FUNCTIONS
Chapter
6
6-6.
Comparison OK output conditions
Conditions to turn on the external output "Calculation OK output" can be set.
0
:
Calculated value only
The output turns on when calculation HI limit/LO
limit is off.
1
:
Calculated value & ch1
The output turns on when calculation HI limit/LO
limit and ch1 HI limit/LO limit are all off.
2
:
Calculated value & ch2
The output turns on when calculation HI limit/LO
limit and ch2 HI limit/LO limit are all off.
3
:
Calculated value & ch1 & ch2
The output turns on when calculation HI limit/LO
limit, ch1 HI limit/LO limit, and ch2 HI limit/LO limit
are all off.
■
Comparison OK output conditions setting method
1.
Select setting mode1.
Press
once.
2.
Set "Comparison OK output conditions setting ."
Press
once.
⇒
"Calculation function select"
is displayed.
Press
, and the highest digit blinks.
Press
once, and the lower digits blinks.
Input the setting value with
.
(
Init
ial value
:
0
)
Press
to validate it.
3.
Press
twice to go back to the indicated
value display
.
Ch1 Ch
2
H I
LO
H I
LO
FNC
H I
Ch1 Ch
2
OK
LO
PEAK
HOLD
H I
LO
H I
LO
H I
Ch1 Ch
2
OK
LO
PEAK
HOLD
H I
LO
H I
LO
Undefined
Calculation comparison timing
0
0 0 0
Calculation comparison OK
Undefined
0:
Calculated value only
1:
Calculated value & ch1
2:
Calculated value & ch2
3:
Calculated value & ch1 & ch2
《
Setting value
》
output conditions
ESC