4 of 33
A.
Introduction:
The UNIPHOS range of gas transmitters provide comprehensive
monitoring of flammable, toxic & Oxygen gas hazards in potentially
explosive atmosphere, both indoor & outdoor.
“
Uniphos-500DT
”
KwikSense-Lite the gas transmitter provides
continuous monitoring of the atmosphere for hazardous gases in the
workplace and is virtually maintenance-free. Its revolutionary
design utilizes advanced microcontrollers and allows for enhanced
diagnostics and fault analysis. Advanced design features make
installation and operation simpler than ever, saving you time &
money. Sensor modules are available for variety of flammable gases,
toxic gases & Oxygen. Plug in sensor replacement is extremely easy
operation.
The transmitter provides 4-20mA output signal which can be connected
to any control system like DCS, PLC etc. Designed with non-volatile
memory, the transmitters have total memory retention capacity. There
is provision to have mute function of the internal relay contacts
during the maintenance.
Users can modify transmitter operation using the LCD/OLED & magnet
switches without ever needing to open the unit. Magnetically coupled
non-intrusive calibration can be easily performed by one person with
ease. Normally, only a periodic calibration check is needed to assure
dependable performance.
The LCD/OLED is an intuitive user interfaces, indicating the
following:
•
Model name & Sr. No.
•
Gas name being monitored and concentration level in ppm, %LEL
or % V/V unit etc.
•
Alarm levels (which are user settable viz. Low and High).
•
Date of last calibration.
•
Prompt to apply the zero gas & span gas during the calibration
mode.
•
Indication if a toxic or combustible gas sensor has “failed”
in the self test or sensor absent.