![Union Community Virdi 4000 User Manual Download Page 36](http://html.mh-extra.com/html/union-community/virdi-4000/virdi-4000_user-manual_842998036.webp)
VIRDI 4000 User Guide
36
Union Community CO., LTd. 44-3 Hyundai Topics Building 5, 6 floor, Bangi-dong,
Songpa-gu, Seoul, Korea 138-050, Tel: 82-2-6488-3000, Fax: 82-2-6488-3099,
E-Mail:[email protected], http://www.unioncomm.co.kr
<User ID Group>
(N=0/Y=1):0
Default setting: ‘0’
Treat first digits of the ID as a group for authentication, so 1:N
authentication can be processed much faster when over 1,000 users are
registered.
If it is set to ‘1’, fingerprint authentication is performed for users starting with
the entered ID. If it is set to ‘0’, treat entered numbers as a user ID and try
user fingerprint and 1:1 authentication for the corresponding ID
Ex.) when a user ID is a 4-digit number and ‘12’ is entered for
authentication, if it is set to ‘1’, 1:N authentication is performed for user
IDs ‘1200’~’1299’. If it is set to ‘0’, 1:1 authentication is performed on
user ID 12 with his/her fingerprint.
When 1:N authentication is set to ‘0’
<Verify Multi-FP>
(N=0/Y=1):0
Default setting: ‘0’
For successful authentication, all registered fingerprints shall be
authenticated after ID (or card) input.
This is used when a high security level is required for special areas. If a user
of ‘ID 0001’ has 3 fingerprints registered to the unit, all 3 fingerprints shall be
authenticated after ID input.
The authentication sequence for the 3 fingerprints does not matter in this
case, but authentication fails if a single fingerprint is not successfully
authenticated
Once the setting is complete, press [ENTER] to move to the upper menu.
3.5.3. Door settings
In the main menu, press [3] to select “3. Option” and the following screen
appears:
1. Application
2. Verify Option
3. Set Doorlock
4. Sound Control
5. Time Setting
6. Other Setting
Press [3] for door settings.