PART I: SPECIFICATIONS
6
Burner model identification
Burners are identified by burner type and model. Burner model identification is described as follows.
Technical Specifications
(*) NOTE ON THE BURNER WORKING SERVICE:
LMV2x automatically stops after 24h of continuous working. The device immedia-
telystarts up, automatically. LMV3x performs countinuous operation (with electrode only).
Type
G325X
Model
M-.
MD. SR.
.
A. 1.
50.
EA.
(1)
(2)
(3)
(4)
(5)
(6)
(7)
(8)
(9)
1
BURNER TYPE
G225X, G270X, G325X
2
FUEL
M - Natural gas, L - LPG
3
OPERATION (Available versions)
PR - Progressive, MD - Fully modulating
4
BLAST TUBE
SR = Standard blast tube + ABS polymer (silenced) air intake
LR = Extended blast tube + ABS polymer (silenced) air intake
5
DESTINATION COUNTRY
* - see data plate
6
BURNER VERSION
A - Standard, Y - Special
7
EQUIPMENT
0 = 2 gas valves
1 = 2 gas gas proving system
7 = 2 gas maximum gas pressure switch
8 = 2 gas gas proving maximum gas pressure switch
8
GAS CONNECTION
50 = Rp2 65 = DN65
80 = DN80 100 = DN100
9
MICRO-PROCESSOR CONTROL
EA = micro-processor control, without inverter
EB = micro-processor control, with inverter
BURNER TYPE
G225X M- G270X M- G325X M- G225X L- G270X L- G325X L-
Output
min. - max. kW
230 - 2250 340 - 2700 620 - 3250 230 - 2250 340 - 2700 620 - 3250
Fuel
Natural gas
I
3B/P
Category
(see next paragraph)
Gas rate- Natural gas
min.- max. (Stm
3
/h)
24 - 238
36 - 286
66 - 344
-
-
-
Gas rate- LPG
min.- max. (Stm
3
/h)
-
-
-
8,6 - 84
12,7 - 101 23 - 121
Gas pressure
mbar
(see Note 2)
Power supply
triphase
220 V/ 230 V 3~ / 380 V/ 400 V 3N ~ 50 Hz
Auxiliary Power supply
220 V/ 230 V 2~ / 220 V / 230 V 1N ~ 50 Hz
Total power consumption
kW
6
8
6
8
Electric motor
kW
5,5
7,5
5,5
7,5
Protection
IP40
Operation
Progressive - Fully modulating
Gas train 50
Valves size / Gas connection
50 / DN50
Gas train 65
65 / DN65
Gas train 80
80 / DN80
Gas train 100
100 / DN100
Operating temperature
°C
-10 ÷ +50
Storage Temperature
°C
-20 ÷ +60
Working service
Intermitent
Note1:
All gas flow rates are referred to Stm
3
/ h (1.013 mbar absolute pressure, 15 °C temperature) and are valid for G20 gas
(net calorific value H
i
= 34,02 MJ / Stm
3
); for L.P.G. (net calorific value H
i
= 93,5 MJ / Stm
3
)
Note2:
Maximum gas pressure = 360 mbar (with
Dungs MBDLE)
= 500 mbar (with
Siemens VGD or Dungs MultiBloc MBE)
Minimum gas pressure = see gas curves.
Note3:
Burners are suitable only for indoor operation with a maximum relative humidity of 80 %
Note4:
with electrode: for safety reasons the burner must stop automatically every 24 hours
Summary of Contents for G225X
Page 41: ...Service manual AZL2x LMV2x 3x Burner Management System M12916CD Rev 3 4 03 2023...
Page 48: ...8 Parameters level heating engineer...
Page 90: ...50 ERROR CODE TABLE...
Page 91: ...51...
Page 92: ...52...
Page 93: ...53...
Page 94: ...54...
Page 95: ...55...
Page 96: ...56...
Page 97: ...57...
Page 98: ...58...
Page 99: ...59...
Page 100: ...60...
Page 101: ...61...
Page 102: ...62...
Page 103: ...63...
Page 104: ...64...
Page 109: ......
Page 110: ......
Page 111: ......