11.0
BATTERY TESTING
11.1
Battery Check
The presence of a battery can be verified without opening the NRT/NRM.
Look for the flashing LED through the window on the front of the NRT/NRM unit.
If the NRT/NRM is in an idle state the LED will flash faintly once every second.
If the LED is not flashing, you will need to open the NRT/NRM and verify the presence of
a battery:
If a battery is installed, the NRT/NRM may be in sleep mode.
To wake the NRT/NRM, remove the battery, leave it out for 3 minutes, then re insert the
battery.
11.2
Battery Replacement
Wait for 3 minutes to allow any residual charge within the NRT/NRM to dissipate.
Replace the battery
The NRT/NRM battery should only be replaced with a SAFT LSH20. This is a spiral
wound Lithium Thionyl Chloride [Li-SOCl2] battery with a terminal voltage of 3.6 volts.
Failure to replace the battery with the correct type may cause communication failure.
For further information on the battery and where to purchase replacements, please refer
to
www.saft.com
WARNING
: Care should be taken when handling lithium batteries as misuse may cause
damage to the NRT/NRM or, the battery cells may explode.
Ensure that the battery terminals are NOT shorted and that there are no loose wires in the
vicinity the battery.