background image

Unicont SPb Ltd 

 

Technical Documentation CH-105 

 

Page 17 

14.

 

Transportation and Storage 

The battery charger shall be stored in heated space at air temperature of +5 º

С 

to +35 º

С 

(maximum  values  of  -30 º

С 

to  +70 º

С

),  at  relative  humidity  of  air  not  exceeding  95 %  at 

temperature of +25 °C and content of dust, oil, moisture and aggressive admixtures in the air not 
exceeding the norms envisaged by GOST 12.1.005-88 for the working zone of production areas. 

The  device  shall  be  transported  in  transport  container  of  the  manufacturer  in  closed 

transport. 

Means of transport: 

 

automobile and railway closed transport (covered wagons, universal containers) 

 

by air (in pressurized and heated bays of airplane) 

 

by sea (in dry service spaces). 

The device shall be transported in accordance with the transport regulations in force for 

the particular transport. 

During  handling  operations  and  transportations  strictly  observe  the  requirements  of 

handling marks on boxes and do not allow bumps and impacts which can affect preservation and 
serviceability of the device. 

Packed devices shall be reliably secured in vehicles. 

After storage in stores or transportation at temperature below  +10 º

С 

the devices shall 

be  unpacked  only  in  heated  spaces  after  keeping  them  unpacked  in  under  normal  climatic 
conditions for12 hours. 

 

 

Summary of Contents for CH-105

Page 1: ...Unicont SPb Ltd Automatic Battery Charger CH 105 Technical Documentation 105 11 27012011 St Petersburg 2011...

Page 2: ...ECTION 11 7 CONNECTIONOFEXTERNALALARMUNIT 12 8 ABC ALARMS AND SIGNALLING 12 9 CONTROLS AND INDICATION 13 10 MENU STRUCTURE AND ADJUSTMENT OF ABC 14 11 ABC FUNCTION OF BATTERY PROTECTION FROM DEEP DISC...

Page 3: ...wer decks and it charges accumulator batteries of various ship equipment electronic cartography devices automatic system radio communication devices etc as well as other industrial transport equipment...

Page 4: ...mitting diode External connected Alarm unit AU 106 In built protection excessive voltage of supply network connection of power supply with reverse polarity stability to power supply loss excessive cur...

Page 5: ...installed in the following sequence 1 Select and prepare the place for installation of the device so as to ensure free access input of cables and termination of their ends Vertical bulkhead inside the...

Page 6: ...Figure 2 3 Bring the cables of connected devices to ABC Use the cable of brand or its substitutes with the appropriate cross section of cores When selecting the cable use information on diameters of...

Page 7: ...ion 110 V bottom upwards Supply voltage selector is located from the right side of power unit 6 Connect the power cable to terminals Input of ABC refer to Para 5 2 5 CAUTION For safety of the personne...

Page 8: ...f terminal BATTERY Output 24 V DC Input AU 106 TS Remote Bat_control Wire cross section 16 mm2 6 mm2 1 5 mm2 5 2 3 Connection of Additional Devices to ABC Besides the accumulator battery the following...

Page 9: ...B by two methods directly to AB circuit refer to Figure 5 or by means of switched connection through special terminals of ABC refer to Figure 6 Direct method of connection is used for loads of any cap...

Page 10: ...sagging of charging voltage when ABC charges deeply discharged battery To ensure reliable supply by reserved load it shall be fed from separate power unit refer to example in Figure 7 24V 12V Load Po...

Page 11: ...e battery in standard mode 4 Protection of ABC from connection of AB with reverse polarity is ensured by means of electromechanical disconnection of ABC charging circuit from AB followed by alarm sign...

Page 12: ...bout emergency situation in ABC operation Alarm situations in which the signalling operates are specified in the table Table 4 Table 4 Alarm situations causing activation of ABC signalling Type of eme...

Page 13: ...al light emitting diodes are intended for display of present values of charging current and voltage of ABC 3 Light emitting diodes Failure Normal and Charging are intended for indication of present op...

Page 14: ...aries within 0 2 16 U Selection of AB charging voltage varies within 9 30 V R Activation of AB function of protection from deep discharge enable 1 disable 0 Before setting the charging current and vol...

Page 15: ...e Use keys and to set the required state of function 1 on 2 off Press key SET to confirm the set value and record it in non volatile memory of the device CAUTION Before starting the function of batter...

Page 16: ...in accordance with the documentation on accumulator battery If it is impossible to know the factory values of battery charging voltage the manufacturer of battery charger recommends to set charging v...

Page 17: ...ransport automobile and railway closed transport covered wagons universal containers by air in pressurized and heated bays of airplane by sea in dry service spaces The device shall be transported in a...

Page 18: ...arketable condition or has a damaged body and other causes beyond the manufacturer s control 4 If self made electrical devices were used 5 If there was an attempt to repair the unit by a person who is...

Page 19: ...number was manufactured and accepted in accordance with the regulatory requirements of the state standards and applicable technical documentation and is suitable for operation Quality control represen...

Reviews: