Warranty 

The manufacturer guarantees the unit CH-105 complies with this manual provided that 

the operation, transportation and storage conditions are adhered to during the warranty period. 

The  unit’s  warranty  period  expires  24  months  from  the  date  of  its  shipping  from  the 

manufacturer’s storehouse. 

Within the warranty period, the owner is entitled for a free repair, or a replacement of a 

separate part, provided that the malfunction occurred through the manufacturer’s fault. 

Warranty repair is provided if the unit is submitted with the manufacturer’s label and a 

legible serial number available on it, as well as this operating manual. 

The manufacturer is not responsible and cannot guarantee the unit’s operation: 

1.  After the warranty period is over; 
2.  In  case  of  the  failure  to  observe  the  unit’s  operation,  transportation,  storage  and 

installation rules and conditions; 

3.  If the unit is in an unmarketable condition, or has a damaged body, and other causes 

beyond the manufacturer’s control; 

4.  If self-made electrical devices were used. 
5.  If  there  was  an  attempt  to  repair  the  unit  by  a  person  who  is  not  an  authorized 

representative of the manufacturer. 

If  the  owner  loses  this  operating  manual  or  the  manufacturer’s  label  with  a  serial 

number, the manufacturer shall not provide their copies, and the owner shall be divested of the 
right for a free repair during the warranty period. 

Upon the warranty expiry, the manufacturer shall facilitate the repair of the unit at the 

owner’s expense. 

Note: in case of warranty repair, the unit’s disassembling from the installation site and 

its delivery to the manufacturer’s service center are done at the owner’s expense. 

Visit  the  manufacturer’s  website 

www.unicont.com

  (section  “support/warranty”)  to 

find: 

 

forms to fill in claims, 

 

full warranty description; 

 

full description of the warranty service rendering procedure. 

 
 
 
The manufacturer service center’s address and contact details:

 

Unicont SPb, Ltd.

 

Bld. 26Е Kibalchich Str., Saint Petersburg, 192174, Russia

 

tel.: + 7 (812) 602 02 64

 

fax: +7 (812) 362 76 36

 

e-mail: 

[email protected]

 

Summary of Contents for CH-105

Page 1: ...Unicont SPb Ltd Automatic Battery Charger CH 105 Technical Documentation 105 11 27012011 St Petersburg 2011...

Page 2: ...ECTION 11 7 CONNECTIONOFEXTERNALALARMUNIT 12 8 ABC ALARMS AND SIGNALLING 12 9 CONTROLS AND INDICATION 13 10 MENU STRUCTURE AND ADJUSTMENT OF ABC 14 11 ABC FUNCTION OF BATTERY PROTECTION FROM DEEP DISC...

Page 3: ...wer decks and it charges accumulator batteries of various ship equipment electronic cartography devices automatic system radio communication devices etc as well as other industrial transport equipment...

Page 4: ...mitting diode External connected Alarm unit AU 106 In built protection excessive voltage of supply network connection of power supply with reverse polarity stability to power supply loss excessive cur...

Page 5: ...installed in the following sequence 1 Select and prepare the place for installation of the device so as to ensure free access input of cables and termination of their ends Vertical bulkhead inside the...

Page 6: ...Figure 2 3 Bring the cables of connected devices to ABC Use the cable of brand or its substitutes with the appropriate cross section of cores When selecting the cable use information on diameters of...

Page 7: ...ion 110 V bottom upwards Supply voltage selector is located from the right side of power unit 6 Connect the power cable to terminals Input of ABC refer to Para 5 2 5 CAUTION For safety of the personne...

Page 8: ...f terminal BATTERY Output 24 V DC Input AU 106 TS Remote Bat_control Wire cross section 16 mm2 6 mm2 1 5 mm2 5 2 3 Connection of Additional Devices to ABC Besides the accumulator battery the following...

Page 9: ...B by two methods directly to AB circuit refer to Figure 5 or by means of switched connection through special terminals of ABC refer to Figure 6 Direct method of connection is used for loads of any cap...

Page 10: ...sagging of charging voltage when ABC charges deeply discharged battery To ensure reliable supply by reserved load it shall be fed from separate power unit refer to example in Figure 7 24V 12V Load Po...

Page 11: ...e battery in standard mode 4 Protection of ABC from connection of AB with reverse polarity is ensured by means of electromechanical disconnection of ABC charging circuit from AB followed by alarm sign...

Page 12: ...bout emergency situation in ABC operation Alarm situations in which the signalling operates are specified in the table Table 4 Table 4 Alarm situations causing activation of ABC signalling Type of eme...

Page 13: ...al light emitting diodes are intended for display of present values of charging current and voltage of ABC 3 Light emitting diodes Failure Normal and Charging are intended for indication of present op...

Page 14: ...aries within 0 2 16 U Selection of AB charging voltage varies within 9 30 V R Activation of AB function of protection from deep discharge enable 1 disable 0 Before setting the charging current and vol...

Page 15: ...e Use keys and to set the required state of function 1 on 2 off Press key SET to confirm the set value and record it in non volatile memory of the device CAUTION Before starting the function of batter...

Page 16: ...in accordance with the documentation on accumulator battery If it is impossible to know the factory values of battery charging voltage the manufacturer of battery charger recommends to set charging v...

Page 17: ...ransport automobile and railway closed transport covered wagons universal containers by air in pressurized and heated bays of airplane by sea in dry service spaces The device shall be transported in a...

Page 18: ...arketable condition or has a damaged body and other causes beyond the manufacturer s control 4 If self made electrical devices were used 5 If there was an attempt to repair the unit by a person who is...

Page 19: ...number was manufactured and accepted in accordance with the regulatory requirements of the state standards and applicable technical documentation and is suitable for operation Quality control represen...

Reviews: