Working temperature
-20..+55 °C
Storage temperature
-60..+70 °C
Weight
1.5 kg
Overall dimensions
200 x 134 x 64 mm
4.
Device installation
Mount unit in easy of access place, for example: vertical wall inside of ship.
Safety precautions
Avoid device sinking in water and water ingress inside device casing.
While disconnecting power supply cable, observe correct procedure for
disconnection of cable contacts, avoid contact with printed circuit board.
Do not use organic solvents during cleaning of device surface to avoid damages of
applied decals.
Prohibited:
to use device in floor-mounted position;
to expose device for mechanical shocks and tensioning of power supply cable;
to use faulty device.
Note:
This device should be mounted at least 1 meter from magnetic compass.
It is recommended to install device in the following order:
remove the device face panel;
firmly secure separated casing without face panel on a vertical wall
route and pass connecting cables from external devices through cable entries;
Arrangement of openings, the spacing between openings and overall dimensions are
indicated in Figure 1.
Caution
The whole equipment being connected to the device must be deenergized for the
period of connection.