Unicont SPb Ltd
Technical Documentation ADPC-101
Page 12
Use key
[SHIFT]
key to change cases.
The status of case can be visually defined by cursor status:
blinking cursor with illumination of font recticle – lower case;
no blinking (underlining) – upper case.
Caution
All tuned options are stored in ROM memory and remain unchanged after power
ON/OFF. If gyrocompass course readings were changed during converter power OFF period,
enter a new current course value to ensure correct operation of device.
Note
In this mode of tuning one may enter a number with floating point and one decimal
point of decimal fractions. If incorrect value is entered (over 359.9) the number will be ignored.
In case of operator idling and selected option unuse timeout (in position 5s, 10s, 15s,
20s, 25s except for OFF) there will be an automatic exit from input mode to review mode of
course and speed values without changing of any option.
Selected options are preserved only after depression on
[ENTER]
.
After selection of gyrocompass and log types and input of initial course value and
reception of trustworthy data, device starts to transmit NMEA signal to both outputs RS-232 and
RS-422/485 in parallel, once per second.
Example.
For input value “320.3” should press:
[1] [3] [2] [0] [SHIFT] [.] [3] [ENTER]
6.
Auxiliary mode for display of signal status at input
terminals.
In this mode display shows logical status of signals at device inputs which may be used
during device deployment.
To go into this mode press on
[9]
key.
logic ‘0’
denotes that a signal level at relevant optically isolated input is below
switching threshold.
logic ‘1’
denotes that a signal level at relevant optically isolated input has exceeded
switching threshold.
123 1st, 2nd, 3rd
gyrocompass’s windings
For input of “closing contact” type log