background image

Unicont SPb Ltd 

 

Technical Documentation ADPC-101 

 

Page 13 

 

logic ‘0’

 denotes that the contact is opened 

 

logic ‘1’

 denotes that the contact is closed. 

The unit will be in this mode until operator initiates exit by pressing on any key. 

 

7.

 

Additional displaying modes 

7.1

 

Total trip displaying 

In  this  mode  display  shows  total  trip  of  a  ship  after  last  nulling  of  total  trip  counter. 

Nulling except after shutdown of converter or with pressing 

[7]

 key by operator. After activating 

this mode upper string of display with log information changed to string with information about 
haul. 

 

To  go into this mode press  on 

[F2]

 key. To  go  out  from  this mode press on 

[F2]

  key 

again. 

NMEA data output in this mode does not stop or change. 

7.2

 

Displaying of ROT (rate of turn) 

In  this  mode  display  shows  current  rate  of  turn  of  a  ship.  After  activating  this  mode 

lower  string  of  display  with  current  heading  information  changed  to  string  with  information 
about ROT. 

To go into this mode press on 

[3]

 key. To go out from this mode press on 

[3]

 key again. 

 

8.

 

Menu functions and changing of settings 

Press  on 

[F3]

  key  and  enter  menu  of  settings.  Use 

[3],  [0]

  keys  (up  and  down)  for 

scrolling between options. 

Use 

[6], [8]

 keys (left, right) to select probable option values. 

Again press on 

[F3]

 key for exit from selected mode. Selected options are stored only 

after pressing on 

[ENTER]

When operator is idling and 

unuse timeout

 option is selected (in positions 5s, 10s, 15s, 

20s,  25s  except  for  OFF)  an  automatic  exit  from  the  menu  is  initiated  without  changes  of  any 
option. 

Summary of Contents for ADPC-101

Page 1: ...Unicont SPb Ltd Analog digital programmable converter ADPC 101 Technical Documentation 101 4 30102013 St Petersburg 2013 v 4 1...

Page 2: ...LATION 5 5 UNIT OPERATION 11 6 AUXILIARY MODE FOR DISPLAY OF SIGNAL STATUS AT INPUT TERMINALS 12 7 ADDITIONAL DISPLAYING MODES 13 8 MENU FUNCTIONS AND CHANGING OF SETTINGS 13 9 EXAMPLE OF CONNECTING A...

Page 3: ...g contact Indication of current speed and course values in built in display Conversion of received data into NMEA 0183 format Transmission of converted course and speed data via standard interface RS...

Page 4: ...s 1 or 2 NMEA refresh 1 2 5 10Hz 2 Output signal format standard line NMEA 0183 with line checksum number of options for line output 63 sets by 3 separate options 3 Format parameters Data bit 8 bit Ra...

Page 5: ...cleaning of device surface to avoid damages of applied decals Prohibited to use device in floor mounted position to expose device for mechanical shocks and tensioning of power supply cable to use faul...

Page 6: ...panel on mounted casing tighten gland seals of cable entries Arrangement of terminal strips on the board and purpose of contacts are stated in Figure 2 Wiring diagram for power supply source output c...

Page 7: ...cted jointly and further are connected to a common gyrocompass wire GND and compass outputs are connected to relevant inputs as designated 2 Inputs for log 2 1 Inputs for log with interface on closing...

Page 8: ...itches J4 J5 J6 J7 J8 or jumpers With closed contacts threshold input voltage is approximately 6 V and about 3V with open contacts J4 J5 J6 J7 J8 or input voltage is approximately 3V input voltage is...

Page 9: ...Unicont SPb Ltd Technical Documentation ADPC 101 Page 9 Figure 3 Wiring diagram for synchro type gyrocompass...

Page 10: ...Unicont SPb Ltd Technical Documentation ADPC 101 Page 10 Figure 4 Wiring diagram for stepper type gyrocompass...

Page 11: ...gyrocompass in use Should received values of compass and log are not trustworthy display with show the sign question at the beginning of relevant line indicator readings during device power ON mode o...

Page 12: ...or OFF there will be an automatic exit from input mode to review mode of course and speed values without changing of any option Selected options are preserved only after depression on ENTER After sele...

Page 13: ...in NMEA data output in this mode does not stop or change 7 2 Displaying of ROT rate of turn In this mode display shows current rate of turn of a ship After activating this mode lower string of display...

Page 14: ...negative as far as synchro type compass is concerned selection of negative polarity causes signal inversion and operation for signal edge shift by 180 degrees as far as stepper type gyrocompass is co...

Page 15: ...backlighting and exit from menu of options or input mode in case of operator idling 5 second 10 second 15 second 20 second 25 second OFF 8 7 Alarm tuning Alarm ON OFF If option is setted device is emi...

Page 16: ...absence of reference signal As far as stepper type gyrocompass is concerned lack of required level As far as synchro type gyrocompass is concerned lack of sine signal differentials emergence of timin...

Page 17: ...Unicont SPb Ltd Technical Documentation ADPC 101 Page 17 9 Example of connecting ADPC 101...

Page 18: ...sport automobile and railway closed transport covered wagons universal containers by air in pressurized and heated bays of airplane by sea in dry service spaces The device shall be transported in acco...

Page 19: ...es You can also send the overage equipment to the manufacturer for its further recycling Proper recycling of the product components will prevent potential negative consequences for human health and th...

Page 20: ...nmarketable condition or has a damaged body and other causes beyond the manufacturer s control 4 If self made electrical devices were used 5 If there was an attempt to repair the unit by a person who...

Page 21: ...serial number was manufactured and accepted in accordance with the regulatory requirements of the state standards and applicable technical documentation and is suitable for operation Quality control...

Reviews: