Unicont SPb Ltd
Technical Documentation ADPC-101
Page 7
Inputs: CS1-, CS1+, CS2-, CS2+, CS3-, CS3+, CSR-, CSR+.
1.1 Synchro type gyrocompass.
Synchro type gyrocompass is connected as follows:
output of 1st winding is connected to contacts CS1+, CS3-;
output of 2nd winding is connected to contacts CS2+, CS1-.
output of 3rd winding is connected to contacts CS3+, CS2-.
output of win ce winding is connected to contacts CSR+, CSR-.
1.2 Stepper type gyrocompass.
Stepper type gyrocompass is connected as follows:
all inputs with sign “-” in designation are connected jointly and further are connected
to a common gyrocompass wire (GND), and compass outputs are connected to relevant inputs
“+” as designated.
2. Inputs for log
2.1 Inputs for log with interface on “closing” contact.
Connector J2
inputs LOG, GND.
2.2 Input for log with stepper type interface.
An input is optically isolated which is capable to change switching threshold.
Connector J2
inputs LOG-, LOG+.
3. Information outputs
Information is relayed through asynchronous serial interface of two types:
RS-232: Connector J3, output TX, common wire GND;
RS-422/485: Connector J3, differential outputs TX- and TX+, common wire GND.
4. Power supply
DC voltage power supply 12..24 V is applied to connector J3.
Power consumption is 150 mA maximum.