Figure 2 Arrangement of terminals on printed circuit board.
To change switching threshold of optically isolated inputs of log and gyro compass, use
DIP-switches J4, J5, J6, J7, J8 (or jumpers). With closed contacts, threshold input voltage is
approximately 6 V and about 3V with open contacts.
J4, J5, J6, J7, J8
or
- input voltage is approximately 3V
- input voltage is approximately 6V
J10:
ADPC-101 terminate channel of interface RS-422
ADPC-101 does not terminate channel of interface RS-422
Contacts J9 and JP1 use for programming and never using during exploitation of unit