8.2.2.
LOG bounce delay
– time for programmable deletion of contact
“bounce”:
10 ms, 20 ms, 30 ms, 40 ms, 50 ms, 70 ms, 100 ms.
8.3
Serial port tuning
8.3.1.
COM baudrate
– baud rate, bit/s:
2400, 4800, 9600, 14400,
19200, 28800, 38400, 57600, 76800, 115200, 230400.
8.3.2.
COM parity
–
parity bit:
NO, EVEN, ODD
(no, even, odd).
8.3.3.
COM stop bits
– number of stop bits:
1 bit, 2 bits.
8.4
Keyboard tuning
Button click
– sound click of depressed key:
Yes, No
.
8.5
Display tuning
DISPLAY REFRESH
- refresh frequency of displayed data: 1, 2, 5 and
10 Hz
8.6
Operator idling (timeout) tuning
Unuse timeout
– time of automatic OFF for backlighting and exit from menu of
options or input mode in case of operator idling:
5 second, 10 second, 15 second, 20 second, 25
second, OFF.
8.7
Alarm tuning
Alarm – ON, OFF.
If option is setted, device is emitted sound when input data from
gyrocompass or lag is incorrect and beginning course value not initialized.
8.8
NMEA tuning
8.8.1.
NMEA REFRESH
– refresh frequency of output data:
1, 2, 5 and
10 Hz
8.8.2.
NMEA ROT fmt
– format of output NMEA line with current ROT
(rate of turn) information:
Disabled
- output of ROT information is disabled
TIROT
- $TIROT,x.x,A*cs
HNROT
- $HNROT,x.x,A*cs
8.8.3.
NMEA GYRO
fmt
– format of output NMEA line with current
heading value:
Disabled
- output of heading value is disabled
AGHDT
- $AGHDT,x.x,T*cs
HEHDT
- $HEHDT,x.x,T*cs
HCHDT
- $HCHDT,x.x,T*cs
SIVHW
- $SIVHW,x.x,T,,,x.x,N,,*cs (mixed format: speed and heading
value in one NMEA line)