![Uniclass Prima IP 16 User Manual Download Page 61](http://html1.mh-extra.com/html/uniclass/prima-ip-16/prima-ip-16_user-manual_839425061.webp)
Prima IP KVM Switch User Guide R1.4
Computer Scanning and Alarms
Do not include in scanning process : If you do not want any KVM port (in this case, it is port 6)
to be included in
Prima IP
auto-scanning, you should check this option to exclude it.
Do not generate alarm : If you do not want the scanning process to generate alarm or SNMP
messages for this computer then you should check this option to exclude it.
Power Management
Power Down Command :
Specifies the power down command sent over the serial control port for
the additional remote power control unit you connect to the serial control port of
Prima IP
, e.g.
“/F016\” to power down power bank 01 port 6 with the cascadable power control module such
as the ioPower; “/F000\” to power off all ports on all bank. To send the power down command to
a specific port over the viewer, just switch to that port and evoke the viewer Quick Menu to click
Power off
Delay (sec.): Specify the delay time between the sending of power down commands and that of
the power on command, when the
Restart Computer
option is enabled and
Prima IP
receiving a
specified alarm (either No Video, Blue Screen, NumLock Test failure). For more details, please
refer to the
Sec ion
4.9, Alarms – e-mail Notifications and SNMP Logging Support for Server
Alerting Events.
The delay time between the power off and the power on command is default to
5 seconds.
t
Power On Command :
specifies the power on command sent over the serial control port for the
additional remote power control unit you connect to the serial control port on the backpanel of
Prima IP
,, e.g. “/O016\” to power on power bank 01 port 6 with the cascadable power control
module such as the ioPower; “/O000\” to power on all ports on all bank. To send the power on
command to a specific port over the viewer, just switch to that port and evoke the viewer Quick
Menu to click
Power on
When using a remote power control device for power control of your connected server, please note that
some newer motherboard form factors, such as ATX, etc, will require BIOS option adjustment to respond to
the resumed power feed from its power bus by your power control device. Usually, you should enable the
Power Loss Restart
option on your Motherboard BIOS (or similar option depending on your BIOS vendor),
so that your connected servers can boot up when your power control device is feeding power to its power bus.
- -
57