background image

Mirage   M-­‐160   Installation   and   Maintenance   Instructions   

5   

4.0

 

Installation

 

In   case   debris   enters   into   the   sprinkler,   the   sprinkler   can   be   damaged   and   the   
installer   can   be   hurt.      Therefore   flush   the   piping   of   both   air   and   debris   
thoroughly   before   connecting   the   sprinkler   to   the   water

   

supply

.   

   

Unexpected   activation   of   the   sprinkler   can   lead   to   severe   injuries,   therefore   
please   ensure   the   assembly   is   complete   before   the   water   supply   is   turned   on.         

   

1.

 

The   M-­‐160   sprinkler   inlet   has   2-­‐1/2”   NPT   threads   

2.

 

For   a   proper   seal,   use   Teflon   tape   only.      Avoid   using   Teflon   paste   and/or   pipe   dope.   

3.

 

Install   the   M-­‐160   sprinkler   per   the   irrigation   installation   details   with   the   
corresponding   ductile   iron   swing   joint   assembly.   

4.

 

For   cold-­‐weather   climates,   consider   an   automatic   drain   valve.   

5.

 

Flush   the   irrigation   mainline   and   sub-­‐laterals   before   inserting   the   nozzle   assembly.      
Orient   the   nozzle   assembly   so   the   main   nozzle   is   vertical   as   shown   in   Figure   5-­‐1.   

6.

 

A   molded   arrow   indicates   the   direction   of   the   main   and   lower   nozzles.      This   
indicator   shall   be   pointed   in   towards   the   field.   See   Figure   6-­‐1.   

7.

 

Adjust   sprinkler   arc   pattern   as   needed.         

8.

 

Locate   a   large   round   brass   nozzle   on   the   side   of   the   internal   drive   assembly.      This   
knob   can   be   turned   counter-­‐clockwise   to   slow-­‐down   the   sprinkler   head   rotation   to   
the   point   were   the   sprinkler   will   sit   in   one   position.      The   default   factory   setting   is   
full   speed   that   takes   about   60   seconds   for   half   arc   pattern   to   complete.   
   
   

   

   

Mirage   Nozzle   Assembly   Orientation   

Figure   5-­‐1   

   

   

Nozzle C

Nozzle B

Intermmediate

Nozzle

!   

!   

Summary of Contents for Mirage M-160-FP-9

Page 1: ...d Maintenance Instructions 1 M 160 FP 9 Operating and Maintenance Instructions Underhill International Corporation 20505 Crescent Bay Drive Lake Forest CA 92630 Phone 949 305 7050 Fax 949 305 7051 www...

Page 2: ...D 4 3 0 TECHNICAL DATA 4 4 0 INSTALLATION 5 5 0 COMMISSIONING 6 5 1 HAZARD NOTES 6 5 2 COMMISSIONING 6 5 2 SETTING THE ARC PATTERN PART CIRCLE MODELS 7 5 4 FULL CIRCLE MODELS 9 5 5 SPEED ADJUST CONTRO...

Page 3: ...ns 2 0 Safety These operation and maintenance instructions provide basic tips for assembly installation operation maintenance inspection and repair Please read these Installation and Maintenance Instr...

Page 4: ...elieving pressure and water downstream of either device before attempting any work The specific security warnings are placed in front of the individual chapters in these instructions 2 5 Dangers When...

Page 5: ...ponding ductile iron swing joint assembly 4 For cold weather climates consider an automatic drain valve 5 Flush the irrigation mainline and sub laterals before inserting the nozzle assembly Orient the...

Page 6: ...ler jet direction A molded arrow on the top of the sprinkler indicates the direction of the water jet see Figure 6 1 Top Cover of M 160 Sprinkler Figure 6 1 To avoid personal injury verify the surroun...

Page 7: ...g final adjustments if needed once a full rotation has been observed Prior to setting the arc adjustment gently pry up the M 160 top cover and pull the kickstand into a downward position to that holds...

Page 8: ...Mirage M 160 Installation and Maintenance Instructions 8 M 160 Sprinkler Figure 8 1...

Page 9: ...n decreasing the speed adjust control on the M 160 sprinkler Locate the round brass knob on the side of the internal sprinkler subassembly Turning the knob counter clockwise will slow down the sprinkl...

Page 10: ...ler has been isolated from the mainline supply and the sub lateral line has been de pressurized The M 160 sprinkler is designed to be serviceable from the top without having to remove the entire sprin...

Page 11: ...Mirage M 160 Installation and Maintenance Instructions 11 Models Manufacturer Prior to 2009 Figure 11 1...

Page 12: ...20 Torx Screwdriver N A For the following maintenance and repair work the internal sprinkler subassembly must be removed 1 Locate and unscrew the 2 qty Allen head fasteners that secure the top of the...

Page 13: ...oximately 5720 F then using a pipe wrench unthread see Figure 13 1 Disconnecting the Brass Riser Pipe from the Internal Sprinkler Subassembly Figure 13 1 7 2 1 Changing the Grooved Ring If the bearing...

Page 14: ...water must be free of debris and sediment Locate the filter and clean as needed see Figure 14 1 Filter for Speed Control Figure 14 1 7 2 3 Cleaning the Piston Drive and Piston Drive Area If the M 160...

Page 15: ...rer the cap on the piston drive may be brass Black vs Gray Piston Drive Cover Figure 15 1 1 Locate and remove the 2 qty Allen head fasteners on the sprinkler cap Set the cap and fasteners to the side...

Page 16: ...ston Drive Figure 16 1 A brass piston drive must be replaced with another brass piston drive A plastic piston drive is incompatible with this model M 160 5 To re install a brass piston drive locate th...

Page 17: ...in nozzle body The piston drive should slowly pull up and out of the piston drives area This may have to be repeated in several other areas around the perimeter of the top until the piston drive begin...

Page 18: ...ring and re use the O ring from the original piston drive Failure to remove and replace the O ring will result in the piston drive not fully seating and engaging See Figure 18 2 Remove and Replace the...

Page 19: ...Press the piston drive assembly downward applying even pressure with each thumb until it seats Figure 19 2 show the piston drive fully seated Fully Seated Piston Drive Figure 19 2 13 Install the uppe...

Page 20: ...ener If the fastener cannot be tightened to be flush with the top of cap then it is contacting one of the molded ribs on top of the piston drive Slightly tighten the cap with the face hole tool The ri...

Page 21: ...n the speed rotation knob to fully open during sprinkler operation to see if any improvement can be obtained If not remove and clean the speed rotation filter Verify the speed rotation knob is fully o...

Page 22: ...s overturned Raise the cover of the M 160 and locate the kick stand to hold the sprinkler in the pop up position Verify the spring stop is seated properly then re adjust Confirm the arc pattern holds...

Reviews: