3-4-7. Startup input sequence in M/S operation / pulse-synchronized operation
1) If you start the system in the M/S configuration, turn on all the power supplies at the same time
or turn on the power supply from the slave.
If the slave is not started immediately after the power supply for the master is turned on,
Warning appears.
The "Warning" display disappears by correctly matching the master setting and the connected
units.
R e a r r o t a r y s w it c h
P le a s e s e t c o r r e c t ly
S e e [ F ig . 3 - 6 ]
C h e c k t h e r e a r r o t a r y s w i t c h
s e t t i n g
C h e c k M / S c a b le c o n n e c t io n
O K
N G
O K
S t a r t o f M / S c o n n e c t i o n
M / S c a b le
P le a s e c o n n e c t c o r r e c t ly
S e e [ F ig . 3 - 5 ]
N G
I n t r o d u c e a ll b r e a k e r s o f t h is p r o d u c t a t t h e
s a m e t im e
o r
C i r c u it b r e a k e r in p u t f r o m s la v e
E R R O R o c c u r r e d
N O
Y E S
P l e a s e d r o p a ll t h e b r e a k e r s o f t h is
p r o d u c t a n d p u t it b a c k in a g a in .
* I f E R R O R o c c u r s s e v e r a l t im e s
T h e r e is a p o s s ib ilit y o f p r o d u c t
f a i lu r e
F r o m t h e m a s t e r f r o n t p a n e l
S e t / c h e c k t h e n u m b e r o f c o n n e c t e d
d e v ic e s
" U N I T " in [ 5 - 1 - 4 . M E N U s c r e e n ]
I t e m r e f e r e n c e
W A R N I N G r e le a s e
M / S c o n n e c t io n s e t t in g c o m p le t e d
N O
Y E S
P le a s e d r o p a ll t h e b r e a k e r s o f
t h is p r o d u c t a n d p u t it b a c k i n
a g a i n .
W h e n r e - lo a d in g , t u r n o n a ll t h e
b r e a k e r s o f t h is p r o d u c t a t t h e
s a m e t im e , o r t u r n o n t h e
b r e a k e r s f r o m t h e s la v e .
Figure 3-9. M/S configuration sequence