DC Pulse Power Supply
【
DC-5-P/DC-10-P
】
4
DESCRIPTION OF FUNCTIONS
35
PARAMETER
Continuous mode
One-pulse mode
Pulse parameter
Pulse parameter
A
B
A
B
MENU/CNFG/ARC/PULS/PARC/1st
8us
5us
5us
5us
MENU/CNFG/ARC/PULS/PARC/2nd
8us
8us
8us
8us
MENU/CNFG/ARC/PULS/PARC/ENBL
100us
100us
100us
100us
PARAMETER
Continuous mode
One-pulse mode
Pulse parameter
Pulse parameter
A
B
A
B
MENU/CNFG/ARC/PULS/PARC/1st
8us
5us
5us
5us
MENU/CNFG/ARC/PULS/PARC/2nd
8us
8us
8us
10us
MENU/CNFG/ARC/PULS/PARC/ENBL
100us
100us
100us
100us
・
DC mode (DCMD)
Produces a DC output.
Even an ARC is generated on the load side, a reverse-pulse output is not produced, and only
the inverter is stopped.
*In comparison with the continuous mode and the one-pulse mode, the ARC energy is increased more.
0V
0A
t 時間
電圧
電流
Figure 4-6: Image of waveform in DC mode
Voltage
Current
Time: t
Selecting the one-pulse mode.
Changing the PARC/2nd from 8 us to 10 us
The other modes remain at 8 us as the
changes are not reflected.