12
The screen shows the nominal voltage of Lithium battery.There are three
kinds of Lithium battery:LiFe(3.3V),LiIo(3.6V)or LiPo(3.7V).This information
is of critical importance that you have to check the battery carefully to make
sure it is set up correctly.If it is different from correct value,explosion can
occur during charge process.
The screen shows the сut-off temperature of Lithium battery.you can press
“DEC”or“INC”to select the сut-off temperature(Temp.Rang:20~80
℃
).The
maximum temperature of the battery can be set during the charge process.
The process will be terminated automatically to protect battery once the
temperature of battery reaches this value.This feature is accomplished
through temperature probe(optional).
GHARGER PRO-8
To avoid from erroneous setting by users,
Charger
Pro
-
8
detects the cell count of
Lithium battery automatically at the beginning of charge or discharge process.
But battery that is deep-discharged can't be detected correctly.To avoid this
error,the time term can be set to verify the cell count by the processor.
Normaly,15 seconds are enough to detect the cell count correctly.You need
to extend the time term limit for the battery of large capacity.But the charge or
discharge process may come to an end within the time term because of the
time limit decided by the wrong count if you set too long time limit for the
battery of small capacity.This may cause fatal error.You have to extend the
time term if the processor detect the cell count incorrectly at the beginning of
charge or discharge process.Otherwise,default value is recommended to use.