Avoid
storing
the
device
outside
the
temperature
range
of
50ºF
(10ºC)
to
95ºF
(35º
C)
as
excessively
cold
or
hot
temperatures
can
damage
the
laser
cartridge
or
reduce
its
lifetime.
Ambient
humidity
levels
must
be
non
‐
condensing.
Providing
a
Suitable
Electrical
Power
Source
The
electrical
power
requirements
can
be
found
either
in
the
“Specifications”
table
in
the
beginning
of
this
manual
or
printed
on
the
sticker
next
to
the
power
inlet
of
the
VersaLASER.
The
VersaLASER
and
VersaLASER
accessories
are
equipped
with
standard
IEC
60320
“computer
style”
power
cord
receptacles.
A
power
cord
may
or
may
not
be
included
with
the
device.
If
the
power
cord
is
not
present,
please
refer
to
the
“Additional
Requirements”
supplement
for
more
information.
Never
remove
the
ground
(earth)
lead
to
the
electrical
cord
and
plug
the
system
into
a
non
‐
grounded
(non
‐
earthed)
outlet
.
Operating
the
device
without
the
ground
connection
is
very
dangerous
and
can
lead
to
a
severe,
if
not
fatal,
electrical
shock.
It
may
also
cause
the
device
to
exhibit
unpredictable
behavior.
Noisy
or
unstable
electricity
as
well
as
voltage
spikes
may
cause
interference
and
possible
damage
to
the
device’s
electronics.
If
electrical
power
fluctuations,
brown
outs,
or
constant
power
outages
are
a
problem
in
your
area,
an
electrical
power
stabilizer,
UPS
(Uninterruptible
Power
Supply),
or
backup
generator
may
be
required.
To
prevent
the
overload
of
your
electrical
power
circuit
or
to
control
an
unstable
or
noisy
electrical
power
source,
it
may
be
necessary
to
connect
the
device
to
a
dedicated
electrical
circuit.
The
device
is
designed
as
a
Class
I,
Group
A,
pluggable
device.
It
is
also
designed
for
connection
to
IT
power
systems.
Extracting
Fumes
and
Particulates
Fumes,
smoke,
and
particulates
are
a
byproduct
of
the
cutting
and
marking
of
materials
in
the
VersaLASER
and
MUST
be
extracted
(vacuumed)
from
the
VersaLASER.
You
may
choose
to
either
exhaust
them
to
the
outside
environment
or
filter
them.
External
Exhaust
(most
common):
We
recommend
that
you
contact
a
local
contractor
to
design
and
install
an
exhaust
system
that
not
only
meets
the
minimum
requirements
of
this
device
but
also
complies
with
local
environmental
laws.
The
exhaust
system
MUST
be
capable
of
supplying
a
minimum
of
150
CFM
(cubic
feet
per
minute)
of
airflow
while
under
a
load
of
6
inches
of
static
pressure
(254
m3/hr
at
1.5kPa).
DO
NOT
install
forward
incline,
backward
incline,
in
‐
line,
or
ventilator
fans
because
these
types
of