-2- USE INSTRUCTIONS TFS 100
31/38
IMPORTANT NOTE:
IF YOUR THERMOFORMER IS EQUIPED WITH A VACUUM PUMP PREPARED TO WORK
WITH GAS MIXTURES CONTAINING > 21 % OF 02 IN CASE AN OIL LEVEL DESCENT
TAKES PLACE STOP THE MACHINE AND PUT IN CONTACT IMMEDIATELY WITH THE
NEAREST ULMA AGENCY. READ CHAPTER VACUUM PUMP
7.3.1 TABLE OF LUBRICATION EQUIVALENTS MANUAL
LUBRICANT
LUBRICATION POINT
POINT
FREQUENCE
CHARACTERISTI
CS
RECOMMEND
ED
FILM ADVANCE CHAIN
1
Every 250H.
Oil based on insoluble
synthetic hydrocarbon
and ester.
FILM ADVANCE
CHAIN
LEVER ELEVATION SYSTEM
2
Each bearings
change
Long-lasting
lubrication
(corr. degree = 0)
ARM ELEVATION
SYSTEME
CROSS-CUTTING GUIDES
4,5
Every 500H
Alimentary synthetic
oil Viscosity: SAE 30
CROSS-CUTTING
GUIDES
TRANSMISIÓN SHAFT
7
Every 500H
Alimentary synthetic
oil Viscosity: SAE 30
TRANSMISIÓN
SHAFT
VACUUM PUMP (EXCEPT
OXYGEN)
-
Every 1000 h
(1
st
change at
100 h)
Alimentary synthetic
oil Viscosity: SAE 30
VACUUM PUMP
(EXCEPT
OXYGEN)
VACUUM PUMP (FOR OXYGEN)
-
No necessary
Stainless oil
VACUUM PUMP
(FOR OXYGEN)
SEE THE LUBRICATION POINTS GRAPHIC IN NEXT PAGES.
CHAIN (1)
GREASERS (3, 4, 5, 6)
Summary of Contents for TFS100
Page 2: ......
Page 4: ......
Page 14: ......
Page 16: ......
Page 26: ...2 USE INSTRUCTIONS TFS 100 10 38...
Page 28: ...2 USE INSTRUCTIONS TFS 100 12 38 3 8 ELECTRONIC CABINET...
Page 40: ...2 USE INSTRUCTIONS TFS 100 24 38...
Page 48: ...2 USE INSTRUCTIONS TFS 100 32 38 GREASERS 9372726 GREASE CUP Lubrication points...
Page 56: ......
Page 58: ...3 SCREEN PP45 2 29...
Page 82: ...3 SCREEN PP45 26 29...