11
Programming and information about the PLC
control
When you for the first time turn on the switch you
will see this information on the display. To switch
between the menus you use button
1
that points to
the left. To program you press in the
white button
to the very right together with button number
4
.
Change of desired value you adjust with button
2
and
3
. To jump between different variables within
the same menu you use button
4
before you save
data. Chosen value is saved with button
menu/ok
.
Menu two mostly handles the time for the start
dose. Here you choose how many seconds the
auger takes to feed 150gr to the optimal start dose
we recommend (approx. 2dl) fuel pellets. As
standard the value is 90 seconds input. The menu
also handles the desired value of the photo
resistance that controls the flame at combustion.
The desired value is adjusted to 10 as standard.
When the resistance feels the flame and reached
input value the burner goes over to phase two in
the combustion. The photo resistance value can
also be read in real time. The photo resistance is
also a part of the safety. .