23
Installation certificate ULMA 3000 TCA
(Mailed to ULMA AB in SVENLJUNGA, SWEDEN)
Customer Information:
Installer / Retailer:
Name:
Company:
Adress:
Adress:
Post code:
Post code:
City:
City:
Phone:
Phone:
Signature of the installer:
Date:
Type of product
Type designation
Serial number
Year of production
Pellet burner
ULMA 3000 TCA
(20-30kW)
Boiler
Check list:
Is our standard auger being used for the burner: Yes
No
Other
brand:………………………………
Spiral size: …….mm. Give engine speed:………rpm.
Have a longer auger been chosen:
Yes
No
(Give length:……….meters)
Adjustment of draft limiter, measured draft is
then provided in the measurement protocol.
Control of storage / pellets feeding.
(The way of the fuel).
Control of the hose between and feed auger,
burner unit, fall shaft, break door in burner.
Measured start dose
: Give amount: ………….gram.
Dosage time:………….sec.
Setting of operation time:………..sec.
Idle time (………….sec)
(Auger on/off during operation).
Flue gas temperature measured 1m down in the top of
the chimney at operation. Give temp value…………………degrees.
Burner ULMA 3000 TCA:
High power
Low power
Auto
Protocol:
Draught -hPa
O2%
CO ppm
CO2%
Flue gas temp
Effect burner (kW)
Give fuel deliverer at the service occasion.
Bulk, small bags, other etc.
If this instruction is not being followed at installation, operation and maintenance ULMA AB is according to existing warranty conditions not bounded.
Printout from flue-gas test: