The ignition element of the burner is efficient and
ignites the burner within 60-90 seconds. The fast
ignition phase and combustion phase do so that the
burner fast becomes stable on the flue gas values
and also give very low CO- content. In phase two
as we call the soft start level, the auger doses,
during the up firing phase, the burner 5 times with
three seconds operation intervals on the auger
before it goes over completely to full effect level.
In the next menu you can read the effect of the
burner. Therefore the measured weight/volume of the
start dose is important in the whole context since the
effect is measured after this and so is the feeding-
capacity and waiting time of the auger. Here you also
adjust the time for the feeding of the auger and
standstill time between the doses. Here you also
choose between high, low or auto burning mode.
In this menu you set the right measured
startdose.Then the power calculation will be right.
You can set the maximum time between the air
cleaning procedures. You can also read the
operation time of the burner and how many times it
has started.