4. Besides the built-in trigger (pic. 1.11) the following accessories can be connected:
• Remote control HTA4 (pic. 25.8)
• Safety foot switch incl. 4m cable FTA4 (pic. 26.2)
The pump recognises the various accessories through a special coding; the forward key (pic. 1.11) will be deactivated
accordingly.
5. The battery and possibly the spare battery will be plugged into the sockets (see pic. 12).
6. The pump is now ready to operate. The LCD display (pic. 1.9) is activated.
7. Select the program for the intended application by turning the selection knob (pic. 1.8) or the data function.
8. The working cycle is initiated by activating the advance function of the ‚ forward and return keys (pic. 1.11)
Attention
The crimping cycle can be stopped at any time by releasing or stepping down the actuator of the safety foot
switch (pic. 26.2).
Once the three step safety foot switch has been stepped down, it can only be reactivated by pushing the reset button
of the foot switch. This reset button is located on the top of the foot switch.
Attention
After having terminated the working cycle and prior to changing the dies remove battery to avoid un-
intended use. Avoid unintended starts. Make sure the switch is in the o
ff
position before plugging in.
For transport turn the program selection switch (pic. 1.8) to position 7 to avoid unintended starts.