HE.17532_F © 07/2016
8
AHP700LUIS
GB
Instruction Manual Battery-hydraulic Pump
authorised
copy
Attention
Maintain power tools thoroughly. Check for functionality or jamming of moving parts, breakage of parts and
any other condition that may a
ff
ect the power tools operation.
The battery-hydraulic pump is equipped with a controller enabling the user to see when the next service is due by
fl
ashing for 20 sec. at the end of a working cycle. When the next service is due after 10.000 cycles the unit must
be returned to an authorised service center (ASC). Failure to observe this request results in loosing the Warranty.
Preventive maintenance serves your safety. Within the determined use of the tool only the batteries are permitted to
be changed by the customers.
Attention
Do not damage the seals of the tool
Attention
Have the power tool repaired by a quali
fi
ed expert or by a Klauke ASC before use.
It is advisable to have the pump serviced by a specialist during regular intervals to safeguard a technically proper
state before use.
Table 3 - Service schedule
What?
When?
Who?
Cleaning
after each use Service personnel
Check oil level
weekly
Service personnel
Check high pressure hose weekly
Specialist
Proper state
quarterly
Electric specialist
Change hydraulic oil
annually
Manufacturer/Specialist
The hydraulic oil has to be completely changed annually or after 10.000 working cycles.
We recommend to have the service done in specialised companies where the save disposal of the oil is guaranteed
for environmental protection.
Attention
Please use only clean, proper hydraulic oil. (Rivolta S.B.H. 11 and other hydraulic oils of similar quality)