HE.17532_F © 07/2016
9
AHP700LUIS
GB
Instruction Manual Battery-hydraulic Pump
authorised
copy
Attention
Hydraulic oils can cause cutaneous eruption (eczema) or other health hazards. Avoid longer skin contact.
Wash your hands carefully after each contact.
Attention
Spilled hydraulic oil has to be absorbed immediately.
4.4 Reference as to which spare parts can be exchanged by the customers
Within the determined use of the tool the customers may only change the oil.
Attention
Do not damage the seals of the pump.
Do not attempt to repair the tool yourself, and do not remove any parts such as screws and other components.
5. Troubleshooting
a.) Constant
fl
ashing/indicating of the red LED (pic 1.10) or the occurence of an acustical warning signal.
see tab. 2. If the failure can not be resolved through the action recommended in tab. 2 return the unit to the
nearest service center (ASC).
b.) The tool or the crimping head loses oil.
Return the unit or the accessories to the manufacturer. Do not open it and damage the seal of the tool.
c.) The red LED
fl
ashes 3x and simultaneously 3 acoustic warning signals occure (see tab. 1).
Serious fault! If this fault occures repeatedly return the unit to an Autorized Service Center (ASC). Do not open
it and damage the seal of the tool.
In case of a one time occurence the connector has to be pressed a second time.