26
3.2.6.2 Operation Procedure (Heating Sleeve)
[Sleeve Procedure]
i.
As shown in the picture below, apply power to the control panel and open
the cover of the heater to prepare.
<Monitor> <Control Panel>
<Heating Sleeve>
ii.
Set the sleeve tube to the area of arc-fused fiber that needs to be
reinforced and place the fiber inside the heater. The connector type should
be set to the right-most position so that sleeve tube moves the heater as
closely as possible.
iii.
Activate the heater after placing the fiber. Cooling fan is run to cool the
tube 20 seconds after heater activation.
Sleeve Tube
Connector
Summary of Contents for KR12A
Page 6: ...4...
Page 18: ...16 3 2 2 Arc fusion splicing assembly Heater Cover Heater...
Page 35: ...33 Install the cooling tray on the rear side of heater as follows...
Page 55: ...53 How to delete i Click ii Select mode to be deleted...
Page 57: ...55 How to delete i Click ii Select mode to be deleted...
Page 61: ...59 The splice mode from No 1 to No 42 can t be edited...