MIA-M10Q - Integration manual
satellites, the services offered by the satellite, the configuration of the receiver (test mode allowed/
disallowed, integrity enabled/disabled) and the signal link quality to the satellite.
If corrections are available from the chosen SBAS satellite and used in the navigation calculation, the
differential status will be indicated in several output messages such as UBX-NAV-PVT, UBX-NAV-
STATUS, UBX-NAV-SAT, NMEA-GGA, NMEA-GLL, NMEA-RMC, and NMEA-GNS. The UBX-NAV-
SBAS message provides detailed information about which corrections are available and applied.
Refer to the interface description [
] for a detailed description of the messages.
The most important SBAS feature for accuracy improvement is ionosphere correction. The
measured data from regional Ranging and Integrity Monitoring Stations (RIMS) are combined to
make a Total Electron Content (TEC) map. This map is transferred to the receiver via SBAS satellites
to allow a correction of the ionosphere error on each received signal.
Message type
Message content
Source
0(0/2)
Test mode
All
1
PRN mask assignment
Primary
2, 3, 4, 5
Fast corrections
Primary
6
Integrity
Primary
7
Fast correction degradation
Primary
9
Satellite navigation (ephemeris)
All
10
Degradation
Primary
12
Time offset
Primary
17
Satellite almanac
All
18
Ionosphere grid point assignment
Primary
24
Mixed fast / long-term corrections
Primary
25
Long-term corrections
Primary
26
Ionosphere delays
Primary
Table 9: Supported SBAS messages
Each satellite serves a specific region and its correction signal is only useful within that region.
Planning is crucial to determine the best possible configuration, especially in areas where signals
from different SBAS systems can be received:
•
Example 1 - SBAS receiver in North America:
In eastern parts of North America, make sure
that EGNOS satellites do not take preference over WAAS satellites. The satellite signals from
the EGNOS system should be disallowed by using the PRN scan mask (configuration key CFG-
SBAS-PRNSCANMASK).
•
Example 2 - SBAS receiver in Europe:
Some WAAS satellite signals can be received in western
parts of Europe, therefore it is recommended that the satellites from all but the EGNOS system
should be disallowed using the PRN scan mask.
Although u-blox receivers try to select the best available SBAS correction data, it is
recommended to configure them to exclude unwanted SBAS satellites.
To configure the SBAS functionality, use the CFG-SBAS-* configuration group.
Parameter
Description
CFG-SIGNAL-SBAS_ENA
Enabled/disabled status of the SBAS subsystem
CFG-SBAS-USE_TESTMODE
Allow/disallow SBAS usage from satellites in test mode
CFG-SBAS-USE_RANGING
Use the SBAS satellites for navigation (ranging)
CFG-SBAS-USE_DIFFCORR
Combined enable/disable switch for fast, long-term, and ionosphere corrections
UBX-21028173 - R01
2 Receiver functionality
Page 19 of 89
C1-Public