WWDZWx User Manual
Date:9-Jun-2021
Ubitech Ltd.
Version:0.3
28
Association Group – 2/3
Parameter No.
0x43 (67)
Name
AG3 - Remote Water Leak Cancellation
Info
Remote Water Leak Cancellation Basic SET
Properties
Size
1 Byte
Min Value
0x00 (0)
Format
Enumerated
Max Value
0x02 (2)
Read only
False
Default Value
0x00 (0)
Altering capabilities
False
Advanced
False
Description
Configure Association Group 3 Basic Set value when Remote Water Leak alarm cancelled
Value
Function
0x01 (1)
Basic ON (0xFF)
0x02 (2)
Basic OFF (0x00)
Parameter No.
0x44 (68)
Name
AG4 - Overheat Trigger Value
Info
Overheat Trigger Value Basic SET
Properties
Size
1 Byte
Min Value
0x00 (0)
Format
Enumerated
Max Value
0x02 (2)
Read only
False
Default Value
0x00 (0)
Altering capabilities
False
Advanced
False
Description
Configure Association Group 4 Basic Set value when Overheat Triggered
Value
Function
0x00 (0)
Disable Basic Set (Send nothing)
0x01 (1)
Basic ON (0xFF)
0x02 (2)
Basic OFF (0x00)
Parameter No.
0x45 (69)
Name
AG4 - Overheat Recover Value
Info
Overheat Recover Value Basic SET
Properties
Size
1 Byte
Min Value
0x00 (0)
Format
Enumerated
Max Value
0x02 (2)
Read only
False
Default Value
0x00 (0)
Altering capabilities
False
Advanced
False
Description
Configure Association Group 4 Basic Set value when Overheat Recovered
Value
Function
0x00 (0)
Disable Basic Set (Send nothing)
0x01 (1)
Basic ON (0xFF)
0x02 (2)
Basic OFF (0x00)