WWDZWx User Manual
Date:9-Jun-2021
Ubitech Ltd.
Version:0.3
26
Temperature Sensor – 3/3
Parameter No.
0x34 (52)
Name
Overheat Cancellation Value
Info
Overheat Cancellation Value auto report
Properties
Size
2 Byte
Min Value
0x0000 (0) = 0°C / 0x0100 (0) = 0°F
Format
Unsigned Integer
Max Value
0x00FF (255) = 255°C / 0x01FF (511) = 255°F
Read only
False
Default Value
0x001E (30) = °C / 0x0156(342) = 86 °F
Altering capabilities
False
Advanced
False
Description
Configure Overheat Cancellation Value Set. (Higher byte 0x00 represents Celsius °C unit, 0x01 represents Fahrenheit °F unit)
Value
Function
0x0000 ~ 0x00FF
From 0°C to 255°C
0x0100 ~ 0x01FF
From 0°F to 255°F
Parameter No.
0x35 (53)
Name
Freeze Trigger Value
Info
Configure Freeze Trigger Report value
Properties
Size
2 Bytes
Min Value
0x0000 (0) = 0°C / 0x0100 (0) = 0°F
Format
Unsigned Integer
Max Value
0x00FF (255) = 255°C / 0x01FF (511) = 255°F
Read only
False
Default Value
0x0000 (0) = 0°C / 0x0168 (360) = 104°F
Altering capabilities
False
Advanced
False
Description
Configure Freeze Trigger Report Value. (Higher byte 0x00 represents Celsius °C unit, 0x01 represents Fahrenheit °F unit)
Value
Function
0x0000 ~ 0x00FF
From 0°C to 255°C
0x0100 ~ 0x01FF
From 0°F to 255°F
Parameter No.
0x36 (54)
Name
Freeze Recover Value
Info
Configure Freeze Recover Report Value
Properties
Size
2 Bytes
Min Value
0x0000 for °C / 0x0100 for °F
Format
Unsigned Integer
Max Value
0x00FF (255) =255°C / 0x01FF (511) = 255°F
Read only
False
Default Value
0x0002 (2) =2°C / 0x0156(342) = 86 °F
Altering capabilities
False
Advanced
False
Description
Configure Freeze Recover Report Value. (Higher byte 0x00 represents Celsius °C unit, 0x01 represents Fahrenheit °F unit)
Value
Function
0x0000 ~ 0x00FF
From 0°C to 255°C
0x0100 ~ 0x01FF
From 0°F to 255°F