WWDZWx User Manual
Date:9-Jun-2021
Ubitech Ltd.
Version:0.3
23
16.10 Configuration CC
-
Note: No Bulk Support equals to True. It will return an Application Rejected Request Command when receiving Configuration
Bulk Set or Get (if received without Supervision encapsulation). It will reset all its configuration parameters if either manually
reset to factory default or receives a Configuration Default Reset Command. It will NOT modify or reset any configuration
parameter when being included or excluded of a Z-Wave network.
Sensor Function
Parameter No.
0x10 (16)
Name
Sensors Function Set
Info
Sensors Function Enable / Disable
Properties
Size
1 Byte
Min Value
0x00 (0)
Format
Bit Field
Max Value
0x0F (15)
Read only
False
Default Value
0x0F (15)
Altering capabilities
False
Advanced
False
Description
Water Leak Probes & Temperature Function Set Disable / Enable *(Default all enabled)
Value
Function
Bit 0
Built-in Water Detection Probe *(Default Enabled)
Bit 1
Remote Water Detection Probe *(Default Enabled)
Bit 2
Overheat Detection *(Default Enabled)
Bit 3
Freeze Detection *(Default Enabled)
Parameter No.
0x11 (17)
Name
Water Leak Cancellation Basic SET
Info
Water Leak Probes Cancellation for AG2 AG3
Properties
Size
1 Byte
Min Value
0x00 (0)
Format
Enumerated
Max Value
0x01 (1)
Read only
False
Default Value
0x01 (1)
Altering capabilities
False
Advanced
False
Description
Configure Water Leak Cancellation Basic SET for Built-in (AG2) / Remote Sensor (AG3) Probes, related parameters 0x41 & 0x43
Value
Function
0x00 (0)
Send Basic SET when Water Alarm Cancelled “
Either
” Built-in “
or
” Remote Water Detection Probe
0x01 (1)
Send Basic SET when Water Alarm Cancelled Built-in “
And
” Remote Water Detection Probe