6.6.1  Trouble Shooting 

If you have problems with processing the grill products or generally with the operation of the unit, 

please check firstly the following points: 

Failure 

Possible reason 

Solution 

Uneven flames 

burner is narrowed 

supply of primary air does work 

correctly 
main nozzle is narrowed 

Clean the burner 

Protect from draft                               
 
Call the service 

Spit rotates hardly 

spits are not adjusted parallel 

Re-adjust the spits 

Spit does not rotate 

motor is not switched on 

Protective circuit breaker has re-

leased 
motor is defect 

Switch on the motor 

Push the protective circuit 

breaker gear 1 x 
Call the service 

Illumination does not work 

Lamp is not switched on 

otherwise 

Lamp defect 

Switch on the lamp 

otherwise 

Call the service 

6.7   Wiring Diagram 

6.7.1  all versions 

230V / 50Hz / 1Ph N 

 

6.8  Spareparts 

Replace defect or faulty parts only by using our original spare parts. Repair works and 

changing of any parts must be carried out by authorized service personnel. Disregarding 

these advices will cause a loss of any warranty claims. Also, all certificates (as there are:  

CE, UL, VDE, GS and others) will not be valid anymore! 

 

Summary of Contents for FF Series

Page 1: ...User Manual Wall of Flame FF Series...

Page 2: ......

Page 3: ...ata 8 4 Initial Installation Procedure 14 4 1 Unpacking 14 4 2 Installation 14 4 3 Electrical connection 15 4 4 Gas connection 15 4 5 Re adjustment 16 4 6 Waste Water Connection 17 4 7 Preparation of...

Page 4: ...following That they know about the basic safety instructions and do know the regulations how to prevent possible accidents That they have read the safety chapter and warnings in this operation manual...

Page 5: ...on regular maintenance of any parts being subject to wear and tear In case of nonprofessional service In case of any force majeure 2 3 Explanation of Symbols and notes for the user Within this operati...

Page 6: ...are only allowed to operate the unit under supervision of a trained and experienced person 2 5 4 Operating the controls Only trained personnel is allowed to operate the controls 2 5 5 Safety check du...

Page 7: ...the manufacturer Never weld on load bearing parts of construction All reconstructions do require a written permission of the manufacturer Improper parts have to be changed immediately Only use origin...

Page 8: ...al effect by glowing glass filaments Illumination by halogen light 3 3 Technical Data 3 3 1 Capacity Depending on the size up to 6 chickens per spit 3 3 2 Dimensions mm Model W x H x D Number of Spits...

Page 9: ...able FF 28 LPG 50mbar 4 130 80 screwed tightly open 20 screwed tightly FF 28 LPG 30mbar 4 140 90 screwed tightly open 20 screwed tightly FF 28 Natural gas H 4 240 50 adjustable open 35 adjustable FF 2...

Page 10: ...F 44 Natural gas H 4 240 50 adjustable open 35 adjustable FF 44 Natural gas L 4 260 50 adjustable open 35 adjustable FF 44 Natural gas E 4 240 50 adjustable open 35 adjustable FF 46 LPG 50mbar 6 130 8...

Page 11: ...s L 30 9 12 3 69 FF 26 Natural gas E 20mbar 30 8 48 3 17 FF 26 Natural gas E 25mbar 27 7 3 17 FF 28 LPG 40 13 87 3 15 FF 28 Natural gas H 40 11 31 4 23 FF 28 Natural gas L 40 12 16 4 93 FF 28 Natural...

Page 12: ...ural gas L 60 18 24 7 38 FF 46 Natural gas E 20mbar 60 16 96 6 34 FF 46 Natural gas E 25mbar 54 14 6 34 FF 48 LPG 80 27 74 6 3 FF 48 Natural gas H 80 22 62 8 46 FF 48 Natural gas L 80 24 32 9 86 FF 48...

Page 13: ...Power kW Electrical connection V N Hz 0085 Differing from a m indications the type plate will be executed suitable for the following countries Netherlands for natural gas L connection pressure 25 mba...

Page 14: ...y that the surrounding area can be cleaned 4 2 2 Place of operation Attention The device must be placed on a level solid and fireproof surface in an well ventilated room under an on site extraction ho...

Page 15: ...cal and technical data of your unit from the nameplate The unit is ready for plug in For power supply a shockproof socket is necessary Make sure the supply cable is protected separately with 16 Amps T...

Page 16: ...2 control of type plate or pressure measurement 4 4 4 Control of function Set the unit into operation according to the manual Check the unit for gas leaks Check the correct adjustment of primary air a...

Page 17: ...the ignition cable from all piezo ignitors Remove the front operation panel carefully after unscrewing it The minimum adjustment nozzle is to be find at the upper front side of the all gas valve Unsc...

Page 18: ...taking up the grill products 2 Fat Drawer catches the meat juice and fat coming out of the grill product 3 Gear chain sets the spit in rotation 4 Spit support used as outer support of spit 5 Control k...

Page 19: ...the key of the piezo igniter After the ignition still push the knob for approx 15 20 seconds For minimum adjustment you have to turn the knob counter clockwise Turn the knob on position 0 in order to...

Page 20: ...ade steel machine working always keep the high grade steel surface clean watch out that there is always enough fresh air on the surface never contact the surface with rusty material never use bleachin...

Page 21: ...ageous anti corrosive properties The corrosion resistance of the rustproof steel has a passive layer which can be formed on the surface by oxidation The oxygen in the air is enough to form a passive l...

Page 22: ...f natural plastic or stainless steel bristles for mechanical cleaning Steel wool or brushes with unalloyed steel lead to external rust caused by abrasion Fresh rust spots can be removed with mild acti...

Page 23: ...nd the bottom plate Remove the ignition cable from the piezo igniter You can remove and replace the piezo igniter by loosening the fixing nut from the front panel The re installation is to be made in...

Page 24: ...rsed sequence 6 5 7 Motor Remove the lower fat drawer and the bottom plate Loosen the 2 screws from the protection plate above the motor and remove it Unplug the motor Loosen the chain tension union f...

Page 25: ...its Spit does not rotate motor is not switched on Protective circuit breaker has re leased motor is defect Switch on the motor Push the protective circuit breaker gear 1 x Call the service Illuminatio...

Page 26: ...r piezo ignitor 1 3m 180710 1 ignition cable for piezo ignitor 1 75m 180711 1 FF26 Description Part No Amount scale light motor 360203 2 scale gas valve 360215 3 drive shaft 180596 1 burner 180590 3 c...

Page 27: ...ng drive shaft 380601 4 ignition cable for piezo ignitor 1 3m 180710 1 ignition cable for piezo ignitor 1 75m 180711 1 ignition cable for piezo ignitor 2 2m 180712 1 ignition cable for piezo ignitor 2...

Page 28: ...1 3m 180710 2 ignition cable for piezo ignitor 1 75m 180711 2 ignition cable for piezo ignitor 2 2m 180712 2 FF38 Description Part No Amount scale light motor 360203 2 scale gas valve 360215 8 drive s...

Page 29: ...1 3m 180710 2 ignition cable for piezo ignitor 1 75m 180711 2 FF46 Description Part No Amount scale light motor 360203 2 scale gas valve 360215 6 drive shaft 180597 1 burner left 180590 6 cast iron fi...

Page 30: ...m 352327 2 temperature probe M8 850mm 352328 2 temperature probe extension M8 M10 600mm 352329 6 switch element for push button 380242 1 push button 380244 1 ignition transformer 380260 1 pilot flame...

Page 31: ...Maintenance 31 printed 06 2020 Subject to change FFUserManual docx 6 9 Declaration of Conformity...

Reviews: