Start-up
ATTENTION! Before every intervention (first assembly, cleaning, installation and replacement of the UV-C-lamp, etc) the power supply of the AlgClear UV-C-device must always be
interrupted!
1. Determine the location for the AlgClear UV-C-device by taking into account the distance to the pond pump and a possibly existing or planned pond filter. If e.g. a water fall exists,
the AlgClear UV-C-device can also be connected at a higher location, to return the UV-C irradiated water to the pond via the water fall.
2. Insert the UVC lamp before starting the device as described on page 2 of this operation manual:
a) Undo the screw-on cover and remove it from the housing (fig. 1.1 and 1.2)
b) Click the UVC lamp into the socket, place the protective cap on to the glass of the UVC lamp and then
reassemble the device (Figs. 1.3 – 1.6)
3. Secure the AlgClear UV-C-device with some stones in such a way that the device is stable and cannot fall into the water. Assembly on a wooden plank is also possible.
4. Fasten both brackets with a clip lock to the AlgClear UV-C-device align it by simply rotating it in such a way that it can later on be installed horizontally or screwed on.
5. Now, shorten the universal hose nipples according to the hose diameters for inlet (pump) and outlet (filter or return into pond).
6. Screw the hose nipples to the inlet and outlet connections. Hand-tight fastening is fully sufficient for tightness. Fastening too tight can cause the opposite or even damage of
the AlgClear UV-C-device or hose nipple.
7. Shorten the pond hose to the required lengths Fit the hose with hose clamps onto the hose nipples. In case of spiral pond hose take care that the hose clamps do not cut into the
spiral windings and no hairline cracks are formed. Should this indeed happen, shorten the hose by the length of the damaged portion.
Notice: Should it still be dripping from the connection between hose and hose nipple, you can stop this by wrapping commercially available Teflon-tape around the hose nipple.
8. Re-check before start-up of the AlgClear UV-C – device that
- the closing cover of the AlgClear UV-C-device is screwed on correctly,
- the inlet and outlet connections at the AlgClear UV-C-device are tightened hand-tight,
- the hose connections between filter pump and pond filter or return to the pond are perfect,
- the operating instruction for the AlgClear UV-C-device have been read and the safety advice has been observed.
9. After this, you can start up the AlgClear UV-C-device in the following sequence:
- Always switch on the pond or filter pump first and check if the pond water flows smoothly through the AlgClear UV-C-device and if there are, possibly, still leaks.
- Only after this, switch on the AlgClear UV-C-device and check the function of the UV-C-lamp through the sight glass (at the front). Hereby, there is no direct danger; the
hazardous UV-C-radiation does not penetrate through the material.
10. Shutting down the plant, e.g. for maintenance, is carried out in reverse order, i.e. always switch off the AlgClear UV-C-device first and only then the garden pond or pond filter
pump.
Maintenance
ATTENTION! The power supply plug must always be pulled out first before any intervention (cleaning, installation and replacement of the UV-C-lamp, etc.)!
The AlgClear UV-C–device should be cleaned at least twice a year, depending on the pollution degree of the pond. Should the algae growth in your pond increase again, the quartz
tube, in which the UV-C-lamp is located, should be cleaned from dirt and lime deposition with a soft cleaning cloth, soaked with a soft cleaning agent (as e.g. vinegar solution). Avoid
scratches on the quartz glass and, if possible, do not hold the glass tube directly with your hands. Already small traces of sweat and fat on the quartz glass will burn into the quartz
glass due to the UV-C radiation and can later on cause a capacity reduction of your AlgClear UV-C-device.
The UV-C-lamps, installed in the AlgClear UV-C have a life of about 5,000 operating hours. After this operating time, the UV-Capacity has reduced so far that the UV-C-lamp must be
replaced. Suitable spare lamps are available from your Ubbink specialist dealer.
Carry out maintenance of your AlgClear UV-C-device as follows:
1. Always switch off first the AlgClear UV-C-device and only then the filter pump.
2. Loosen the hose connection and let the water drain from the AlgClear UV-C-device.
3. After this, open the fastening clips and take the AlgClear UV-C–device out of the brackets.
4. To remove the glass, bulb refer to the drawings on page 2 of this operating manual.
a) Undo the screw-on cover and remove it together with the lamp (Figs. 1.1 and 1.2).
b) Now carefully remove the glass bulb with the help of a 10 or 20-cent coin (Figs. 1.3A and 1.3B)
5. Clean the housing and where necessary, replace the UVC lamp
6. After carried out maintenance re-assemble everything in reversed order. Hereby, observe the correct fit of the seal rings located inside.
8. After this, switch on again the filter pump first and then the AlgClear UV-C-device.
Storing/wintering
The AlgClear UV-C device must be disassembled in case of frost and stored frost-free. Prior to this, thorough cleaning should be carried out and the device checked for damages.
Guarantee
We guarantee this product for 3 years against provable material and manufacturing faults; starting from the date of purchase. The original purchasing proof must be presented for
claims under this guarantee. The guarantee does not cover the luminous elements (UV-C-lamp), glass breakage of quartz glass and UV-C-lamp, as well as complaints which have been
caused by assembly and operating faults, insufficient care, frost effects, improper repair attempts, use of force, third party fault, overload, mechanical damage or impact of foreign
bodies. Also excluded from the guarantee are all complaints regarding parts damages and/or problems, which are due to wear.
3
1
Operating Instruction Ubbink AlgClear UV-C
Environmental Protection
Waste electrical products should not be disposed of with household waste. Please recycle where facilities exist.
Check with your Local Authority or retailer for recycling advice.
Manual algclear 2018 CB.indd 4
02.11.18 13:51
Summary of Contents for AlgClear UV-C 2500
Page 58: ......