NOTE: Each oven has been factory tested and adjusted prior
to shipment. It may be necessary to further adjust the oven
as part of a proper installation. Such adjustments are the
responsibility of the installer. Adjustments are not considered
defects in material and workmanship, and they are not
covered under the original equipment warranty.
Lighting
1. Turn on main gas valve. Remove the lower front
cover and the service panel above the control panel.
Drop the control panel and leak test all fi ttings and
connections upstream from the service valve located on
the redundant combination gas valve. Should any gas
leaks be detected, turn OFF main gas valve, correct the
problem and retest.
2. Open
shutoff valve located on the redundant
combination gas valve. Activate control panel and set to
desired temperature. The burners are ignited by direct
spark. Check all fi ttings again and correct any leaks and
recheck.
Replace all service panels and covers before operation.
NOTE: All electronic ignition systems are supplied with a
redundant gas valve. Therefore, the unit is not supplied with
an external pressure regulator.
NOTE: During installation there will be air in the gas line. This
air will have to bleed off before ignition can be established.
The electronic ignition system has a ninety second lock-out
as a safety device on all units. Therefore, several attempts
may be required before pilot ignition is established, wait fi ve
minutes after each attempt.
FOR YOUR SAFETY: KEEP YOUR APPLIANCE ARE FREE FROM
COMBUSTIBLES.
To Conserve Energy
Do not waste energy by leaving controls at high temperature
settings during idle periods. Lower settings will keep
oven warm and ready for next use period. Summit 40
Series controls have an auto setback feature that is user
programmable to help with these applications.
TESTING AND ADJUSTMENTS
Termination Less than 10 feet (3 meters) from ridge
Termination More than 10 feet (3 meters) from ridge
Less than 10 feet (3 meters)
More than 10' (3 meters)
2' (60cm)
Min.
3' (90cm) Min.
3' (90cm) Min.