TYROLIT
Hydrostress AG
Page 20
Faults
Faults
Possible cause
Solution
No water emerging
Water line blocked
X
Clean the water line.
Water valve on the supply or water hose
are closed
X
Open the water valve.
Insufficient water pressure
X
Make sure that the water pressure is at least 2 bar.
Water filter is blocked
X
Remove filter and clean
X
Contact TYROLIT Hydrostress AG customer service.
Switch for the radio remote controller
defective
X
Contact TYROLIT Hydrostress AG customer service.
Uncontrolled water leak
• Water valve on the control unit is
defective
• Switch for the radio remote controller
defective
X
Stop water leaks using the hose water valve.
X
Contact TYROLIT Hydrostress AG customer service.
Group alarm on the remote controller
X
See chapter entitled «Reacting to displays».