Deactivating EMERGENCY STOP
If the EMERGENCY STOP is activated on the radio remote controller, the radio and battery light
(8) flashes.
Deactivating EMERGENCY STOP
The following controls must be moved the 0 position:
Feed potentiometer (6).
Feed joy stick (10).
Main motor On/Off (7).
Turn the EMERGENCY STOP button (3) clockwise.
Press pulse switch control unit (4) to the ON position.
After termination of work
Proceed as follows:
X
Turn the main switch on the control unit WSE2226
to the 0-position.
X
Withdraw the mains plug (Control unit WSE2226
).
X
Disconnect the water hoses from control unit WSE2226
.
X
Blow out the water from all the lines (blow out pump).
X
Disconnect electric cable.
X
Clean the control unit WSE2226
, the remote controller and the cable with a damp
cloth.
Cleaning using high pressure cleaning equipment is not permitted.
Products containing cleaning agent can damage parts of the control unit WSE2226
, the
radio remote controller and the cable.