Servicing and maintenance
Cleaning using high pressure cleaning equipment is not permitted.
Cleaning using high pressure cleaning equipment can damage the control unit and the remote
controller.
Products containing cleaning agent can damage parts of the control unit WSE2226
, the
radio remote controller and the cable.
Clean water filter
Clean water filter
6
Maintenance and servicing table
Bef
or
e star
ting
up
O
n finishing
wo
rk
W
eek
ly
A
nnually
A
ft
er faults
A
ft
er damage
Electrical system
X
Check the condition and cleanliness
of electric cables, plugs/connectors
and switches.
X
X
X
X
X
Check the condition and cleanliness
of connections.
X
X
X
X
Water economy
X
Check water lines for cleanliness and
leaks.
X
X
X
X
X
Clean water filter.
X
X
X
X
Blow out the water if there is a risk of
frost.
X
X
X
Entire WSE2226
control unit
X
Clean with damp cloth
no high pressure cleaner
X
Service
X
To be performed by TYROLIT Hydros-
tress AG or an authorised workshop.
First service after 100 operating hours
Further services after every further 200 operating hours
6.1