Faults

7

Faults

Faults

Possible cause

Solution

Control unit

 

does not run although the 
mains cable is connected

Control unit is switched off

 

X

Switch control unit on, see Chapter 4.

Mains cable is defective

 

X

Replace the mains cable.

No voltage at the power supply (build-
ing site)

 

X

Check the power supply.

Power supply phases incorrectly  
connected

 

X

Check the power supply.

Phase missing

See the chapter 5 entitled «Reacting to displays».

The control unit starts and 
then cuts out again

Building site power supply cut-off unit 
trips

 

X

Check and if necessary adapt the cut-off protection.

 

X

If necessary change the power supply.

 

X

See chapter entitled «Reacting to displays».

No power, even though 
the control unit

  

is running

Incorrect voltage
Defective main motor

 

X

Make sure that the control unit voltage and frequency 
match the mains supply specifications.

 

X

Contact TYROLIT Hydrostress AG customer service.

The control unit

 

suddenly cuts out

Over or under voltage

 

X

Check the power supply. Refer to fault indicator.

Cross section of power supply cable too  
small

 

X

Check the power supply.

Defective plug connection

 

X

Check the plug connection.

 

X

Check the power supply.

Group alarm

 

X

Refer to fault indicator

Main motor is not running

•  Main motor potentiometer is in  

0-position

•  Defective main motor On / Off switch 

on remote controller

The remote controller 'ready to operate' 
light does not come on.

 

X

Contact TYROLIT Hydrostress AG customer service.

 

X

Do not start control unit, see Chapter 4.2

EMERGENCY STOP activated

 

X

Deactivate EMERGENCY STOP, see Chapter 4.10.

Overheating

 

X

Check the water circuit and the plug-in couplings.

 

X

Refer to fault indicator.

No water

 

X

Switch on the water supply.

 

X

Refer to fault indicator.

Remote controller  
not working

Rechargeable battery or battery have 
too little  
charge

 

X

Replace rechargeable battery and recharge or install  
cable operation.

 

X

Replace batteries.

Feed potentiometer indi-
cates no function

•  Defective potentiometer in the remote 

controller

•  Feed motors not connected
•  Defective feed motor
•  Joystick is in the zero position

 

X

Contact TYROLIT Hydrostress AG customer service.

 

X

See Chapter 3.1 / 4.6 / 4.7

Feed motor fails to 
build up power

Remote controller potentiometer is de-
fective or in the 0-position 

 

X

Contact TYROLIT Hydrostress AG customer service.

 

X

See Chapter 4.7.1

Defective cable

 

X

Contact TYROLIT Hydrostress AG customer service.

Motor fault

 

X

Contact TYROLIT Hydrostress AG customer service.

Summary of Contents for WSE2226

Page 1: ...Operating Instructions Control unit WSE2226 Index 000 Original operating instructions 10991502 en 15 11 2016...

Page 2: ...T Hy drostress replacement parts can guarantee quality and interchangeability If maintenance work is neglected or carried out inexpertly we will be unable to honour our warranty obligations Any repair...

Page 3: ...ing machine continuing to run after an acci dent X X Ensure that the EMERGENCY STOP button can be reached quickly Electric shock from live cables and connectors X X Switch off the control unit WSE2226...

Page 4: ...nnector 12 Reset button 6 Water nipple water inlet 13 Radio remote controller 7 Water connection water outlet Main components of radio remote controller Main components of remote controller 1 Feed pot...

Page 5: ...ly charged battery is approximately 12 hours A shorter operating period can be expected at low temperatures The reception distance is 25 m Battery operation The battery holder is included in the scope...

Page 6: ...ed Accessories 1 2x Interchangeable rechargeable batteries No 10984306 2 Rechargeable battery charger No 10984305 Rechargeable battery charger with 10 30 VDC connection No 10984840 3 Remote control ca...

Page 7: ...upply 9 9 Connectors plugs are clean 9 9 Cables are undamaged X X Connecting the mains and water supply 9 9 The power supply is earthed and fitted with a residual current operated protective device FI...

Page 8: ...k switch Traverse feed 8 Main motor potentiometer 2 Water On Off 9 Diameter selector switch 3 EMERGENCY STOP 10 Feed joystick 4 Pulse switch control unit 11 Main switch Control unit 5 Starter switch 1...

Page 9: ...ng the starter switch 5 Warning lights radio and battery at first show red An audible signal sounds simultaneously Indicators flash coloured Second audible signal sounds Indicators show coloured Warni...

Page 10: ...radio link is interrupted another transmitter range empty battery the systems immediately go into EMERGENCY OFF mode New frequency search You can select the next frequency by switching the start swit...

Page 11: ...X X Turn the main motor 8 potentiometer to the 0 position X X Press the switch main motor 7 to I X X Select the desired output level see 4 5 X X Turn the main motor 8 potentiometer slowly to 100 power...

Page 12: ...e controlled via the potentiometers Power control Feed motor potentiometer 6 Main motor potentiometer 8 Adjusting the feed The feed movements are selected with the joystick Adjusting the feed During t...

Page 13: ...off electric motor 7 On Off main motor X X Turn off cooling water switch 2 Water On Off X X Close water valve on control unit WSE2226 X X Turn the start switch 5 on the remote controller to the 0 posi...

Page 14: ...n After termination of work Proceed as follows X X Turn the main switch on the control unit WSE2226 to the 0 position X X Withdraw the mains plug Control unit WSE2226 X X Disconnect the water hoses fr...

Page 15: ...Symbols on the control unit Symbols on the remote controller 1 Service 8 Radio and battery remote control 2 Control unit external fault 9 Cooling water 3 Fault within the control unit 10 Group alarm...

Page 16: ...X X Contact TYROLIT Hydrostress AG customer service X X Check network connection Lights up red Over heated cooling element control unit main motor The control unit will not start X X Check cooling Wa...

Page 17: ...o light shows No water flow The control unit will not start motor does not run X X Press the cooling water button LED shows blue Lights up red or flashes Group alarm on the control unit When the pulse...

Page 18: ...ng work Weekly Annually After faults After damage Electrical system X X Check the condition and cleanliness of electric cables plugs connectors and switches X X X X X X Check the condition and cleanli...

Page 19: ...Check the plug connection X X Check the power supply Group alarm X X Refer to fault indicator Main motor is not running Main motor potentiometer is in 0 position Defective main motor On Off switch on...

Page 20: ...ilter is blocked X X Remove filter and clean X X Contact TYROLIT Hydrostress AG customer service Switch for the radio remote controller defective X X Contact TYROLIT Hydrostress AG customer service Un...

Page 21: ...Frequency converter Max current consumption 38 A Power With 32 A power supply net work 17 kW With 63 A power supply net work 26 kW Internal control voltages Controller remote controller 24 VDC 3 6 VDC...

Page 22: ...t complies with the following direc tives and standards Applied directives 2006 42 EG 2014 30 EU 2012 19 EU 1999 5 EG Applied standards EN 15027 2007 A1 2009 EN 12100 2010 EN 60204 1 2006 A1 2009 EN 6...

Page 23: ...TYROLIT Hydrostress AG Page 23 Spare parts 10...

Reviews: