A–4
iSTAR eX Installation and Configuration Guide
Diagnostic and Status Messages
Rotary switch SW1 positions 0 through F.
Activate status messages (with ICU Block on or off)
Activate diagnostic tests for troubleshooting
Table A.1 shows Rotary switch settings and descriptions.
Table A.1: Sw1 Rotary Switch Settings
Rotary Switch
SW1 Setting
Description
0
ICU Block Off (Read/Write/Update) - Display General Messages
F
ICU Block On (Read only) - Display General Messages
1
Display card data from last card read, 7 second LCD display (slow mode).
2
Display card data from last card read, 2 second LCD display (fast mode).
3
Display supervised input changes, 2 second LCD display (slow mode)
4
Display supervised input changes, 1 second LCD display (fast mode)
5
Display manual output changes (include readers and R/8 boards), 2 second LCD
display (slow mode).
6
Display output changes (does not include readers and R/8 boards), 1 second LCD
display (fast mode)
7
Activate output test mode (include readers and R/8 boards).
8
Test Ethernet #1 and Ethernet #2 ports and devices
9
Not used
A
Not used
B
Not used
C
SWH use only. Do not set to this position.
D
Clear memory. (Press GCM reset, wait for LCD instructions, set rotary switch back to
0
or
F,
press
reset
again
.
).
E
SWH use only. Do not set to this position.
Summary of Contents for iSTAR eX
Page 12: ...Table of Contents xii iSTAR eX Installation and Configuration Guide...
Page 58: ...Backup and Restore 1 38 iSTAR eX Installation and Configuration Guide...
Page 146: ...Starting the ICU 5 12 iSTAR eX Installation and Configuration Guide Figure 5 4 ICU Main Window...
Page 200: ...STAR eX Diagnostic Tests 7 10 iSTAR eX Installation and Configuration Guide...
Page 212: ...A 12 iSTAR eX Installation and Configuration Guide...