3
3.2.2 Select the appropriate gland depending on the cable diameter.
3.4.1 Install the splicing tray by pushing the lip on the groove plate
slightly up with the tray and move the tray lateral from left to right into
the hinging cavity.
Note
. 1 for single element start on the second position
leaving one position open between each of the trays.
2 For ribbon 4-8 trays the tray hinges have to be
inserted from right to left.
3.2.3 Install the glands in the selected ports by tighten the nut on the
inside of the box, do not forget to install the rubber ring on the outside
of the box.
3.3
Installation of wraparound groove plates
3.3.1. Take the groove plates and slide the long protrusions into the
left bracket of the UMS bracket.
3.3.2. Pull on the long snapfit towards the profile till it clicks in the
UMS bracket, start on the FAS block without leaving gaps between the
plates.
3.4
Installation of the trays