Tomcat i875PR S5102-P
Chapter 4: SATA/RAID Setup (for SATA RAID model)
Rebuilding A Mirrored Array
The Rebuild Array <5> Menu option is necessary to recover from an error in a mirrored disk
array. You will receive an error message when booting your system.
NOTE: Drives MUST be replaced if they contain any physical errors.
Follow these steps BEFORE using the Rebuild Array menu option:
1. On bootup, the Startup BIOS will display an error message identifying which drive has
failed.
2.
Press <Ctrl-F> keys to enter FastBuild Main Menu.
3.
Select submenu Define Array <3>.
4.
Select the failed array and identify the Channel and ID of the failed drive.
5.
Power off and physically remove the failed drive.
6.
Replace the drive with an identical model.
7.
Reboot the system and enter the FastBuild Main Menu.
8.
Select the <5> Rebuild Array option. The following screen will appear.
FastBuild (tm) Utility 2.xx (c) 2002-2005 Promise Technology, Inc.
Array No RAID Mode
Total Drv Capacity(MB) Status
Array 1
Mirror 2
16126
Critical
Array 2
——
——
—— ——
Array 3
——
——
—— ——
Array 4
——
——
—— ——
[
↑
] Up [
↓
] Down [ESC] Exit [Enter] Select
[ Rebuild Array Menu ]
[ Keys Available ]
9.
Highlight the array whose Status is “Critical”.
10. Press [Enter]. The following screen will then appear (see next page).
4-14
http://www.tyan.com