background image

Page | 8 

 

Telnet Commands 

COMMAND 

DESCRIPTION 

PARAMETER 

IPCONFIG

 

Display the current IP 
configuration

 

NONE

 

SIPMODE 

Set Ethernet IP mode 

N = STATIC/DHCP 

SIPADDR XXX.  
XXX.XXX.XXX

 

Set Ethernet IP address

 

XXX = 0 to 255

 

SNETMASK XXX.  
XXX.XXX.XXX

 

Set Ethernet Subnet mask

 

XXX = 0 to 255

 

SGATEWAY XXX.  
XXX.XXX.XXX

 

Set Ethernet gateway

 

XXX = 0 to 255

 

VER

 

Show unit firmware 
version

 

NONE

 

FADEFAULT

 

All configurations set to 
factory default

 

NONE

 

ETH_FADEFAULT

 

All Ethernet 
configurations set to 
factory default*

 

NONE

 

REBOOT

 

System reboot

 

NONE

 

HELP (?)

 

Show command list

 

NONE

 

HELP N

 

Show description of 
command

 

N = COMMAND 
NAME

 

RELAY N N1

 

Relay control

 

N = PORT (1 or 2)   N1 
= OPEN/CLOSE/ 

TOGGLE

 

LEDBLUE N N1

 

LED blue backlight 
control

 

N = BUTTON (1-15/16) 

N1 = % (0-100)

 

LEDRED N N1

 

LED red backlight control

 

N = BUTTON (1-15/16) 

N1 = % (0-100)

 

 

 

 

N1=% (0-100)

 

Summary of Contents for 1T-CL-322-EU

Page 1: ...Page 1 Instruction Manual 1T CL 322 EU 15 Button Wall Plate Control Keypad 1T CL 322 US 16 Button Wall Plate Control Keypad 1T CL 322 1T CL 322...

Page 2: ...ontrols and Functions 7 Front and Rear Panel 7 Telnet Commands 8 Software Application 10 Telnet Control 11 WebGUI Control 12 Macro Settings 13 Extension Macros 16 Command Settings 17 Command List 18 S...

Page 3: ...Page 3 Updating Firmware 26 Specifications 27 Acronyms 27 Limited Warranty 28 Regulatory Compliance 29 Contact Information 30...

Page 4: ...n or be liable for any direct indirect or consequential damages or loss in connection with the purchase or use of this hardware software or manual The sole and exclusive liability to the supplier and...

Page 5: ...t use the PSU if it is damaged Do not allow anything to rest on the power cabling or allow any weight to be placed upon it or any person walk on it To protect the unit from overheating do not block an...

Page 6: ...DC power supply Package Contents Wall Plate Control Keypad USB Type A to Mini USB OTG Connector 3 5mm Terminal Block 2x EU and 1x US models 5 Volt 2 6 Amp DC Power Adaptor Pre Printed Button Label St...

Page 7: ...hernet Connect to an active Ethernet connection or direct to a PC or Laptop This connection supports PoE when connected to an Ethernet switch that supports 48v PoE The unit can be powered without the...

Page 8: ...t Ethernet gateway XXX 0 to 255 VER Show unit firmware version NONE FADEFAULT All configurations set to factory default NONE ETH_FADEFAULT All Ethernet configurations set to factory default NONE REBOO...

Page 9: ...e Press and HOLD N PORTNUMBER MACRO RUN N Run specific Macro N MACRO ID 1 30 32 MACRO STOP Stop Macro NONE MACRO STOP Stop specific Macro N MACRO ID 1 30 32 MACRO_FA DEFAULT All Macro control set to f...

Page 10: ...SW application Click on Find Devices on Network and a list of the devices connected to the Control System will show up The user may use the discovered IP Address to access the unit Open your internet...

Page 11: ...e Version The hardware version of the unit Description A short description of the unit Web GUI Link to open the web interface in your browser Telnet Control Before attempting to use the Telnet control...

Page 12: ...the web address entry bar A security page will appear to ask for User and Password please key in admin for the Username and adminpw for the password then click Submit these are factory default passwor...

Page 13: ...Light bar allows the user to change the LEDs brightness based on the original percentage setting The Demo Mode switch turns the demo mode on and off When turned on if there has been no interaction for...

Page 14: ...to edit the commands for the macro sequence Use up down arrows to move the commands up or down in the sequence To edit existing commands use To delete commands use Please note this function will imme...

Page 15: ...e time in milliseconds between sending commands Interface The interface that you wish to control SysCMD Telnet and Relay Telnet IP This is the address of the unit you wish to control or send commands...

Page 16: ...assure a successful transmission Once you have completed your editing click on Save Changes When selecting a Relay interface the relay number must also be selected Click on Save Change to confirm the...

Page 17: ...t will reduce the overall number that can be stored To add or edit a command click on the selected Edit button the Command Edit window will appear where you can enter the command parameters Please not...

Page 18: ...EN CLOSE TOGGLE RELAY 1 CLOSE Can be used to close specific Relay s In this example Relay 1 will be closed RELAY 1 OPEN Can be used to open specific Relay s In this example Relay 1 will be opened RELA...

Page 19: ...LEDs In this example the red LEDs on all buttons will be set to 50 brightness BACKLIGHT N All LED backlight control common N 0 100 BACKLIGHT 50 Can be used as a common command to change the state of a...

Page 20: ...time Note During a power outage the scheduling system can support up to 48hrs of internal CPU power Once the back up power is exhausted the system time will reset to factory default 2015 01 01 00 00...

Page 21: ...ttings to configure the control panel s network interface IP Mode Static or Dynamic modes IP address Discover or enter an IP address for the unit Netmask Discover or enter a netmask address Gateway Di...

Page 22: ...ew password checks for password match to avoid typographical errors Web Login Timeout The number of minutes before the system logs out for user inaction Download Configuration This allows for the user...

Page 23: ...r disable daylight savings time If enabled the start and end times and dates are required to be entered for your specific geographical region When setting the System Time it is easiest to click in the...

Page 24: ...mples of how to create command strings to control equipment via the Ethernet port in this instance to recall presets on certain tvONE C2 and C3 products C2 2855 and C3 510 The C2 2855 requires two com...

Page 25: ...d preset 1 login admin adminpw x0dpreset take 1 x0dlo gout x0d x0a Button Labels A sheet of self adhesive button labels are included These can be applied to the buttons to identify each function Blank...

Page 26: ...anel For the EU version use a small screwdriver and lever it off using the two slots provided at the bottom of the plate 4 Connect the USB thumb drive to the mini USB socket using the enclosed adapter...

Page 27: ...harge 6 kV contact discharge EU 4 kV contact discharge US Dimensions including front panel connectors and buttons 87mm H x 149mm W x 31mm D EU version 114mm H x 116mm W x 47mm D US version Weight 226...

Page 28: ...tive LCD panel manufacturer Such specific LCD panel warranties are available upon request to tvONE Should a product in tvONE s opinion prove defective within this warranty period tvONE at its discetio...

Page 29: ...any damage arising from the use of such defective products whether such damages be direct indirect consequential or otherwise and whether such damages are incurred by the reseller end user or any thir...

Page 30: ...el 44 0 1843 873311 Fax 44 0 1843 873312 Sales sales europe tvone com Tech Support tech europe tvone com Version Control 1T CT 322 manual Version 1 1 Date January 18 2016 Author Scott Coltham Copyrigh...